September 30, 2023Journal of Interventional Cardiac Electrophysiology37 citationsOpen Access

Characterization of durability and reconnection patterns at time of repeat ablation after single-shot pulsed field pulmonary vein isolation

MRMartin H. RuwaldMHMartin HaugdalRWRené Worck

Key Result

Complete durable pulmonary vein isolation was observed in only 42% of patients undergoing a repeat procedure for recurrent arrhythmias after index single-shot pulsed field ablation.

Study Design

Type

Observational (n=26)

Multicenter

No

Structured PICO

P
Population
26 patients (mean age 65, 58% female) undergoing a clinically indicated repeat procedure for symptomatic recurrent arrhythmias at a mean of 292 days after an index single-shot pulsed field ablation for atrial fibrillation.
E
Exposure
3D high-density or ultra-high-density bipolar voltage amplitude mapping and ad-hoc re-ablation by radiofrequency or focal pulsed field ablation (PFA)
O
Outcome
Electrophysiological findings at time of repeat procedure, including complete durable PVI rate, durable vein isolation rate, and reconnection patterns/gap locationssurrogate

In patients undergoing repeat ablation for recurrent arrhythmias after single-shot pulsed field ablation, durable pulmonary vein isolation was found in less than half of patients, with reconnections preferentially located at the anterior aspects of the right-sided pulmonary veins.

Limitations

  • Single-center study with limited sample size
  • No long-term follow-up available after the repeat procedure
  • Indication criteria for repeat ablation were not uniform and based on a case-to-case scenario
  • Includes very early experiences and implementation phases of PFA at the center

Abstract

BACKGROUND: Pulsed field ablation (PFA) is a novel method of cardiac ablation where there is insufficient knowledge on the durability and reconnection patterns after pulmonary vein isolation (PVI). The aim of this study was to characterize the electrophysiological findings at time of repeat procedure in real-world atrial fibrillation (AF) patients. METHODS: Patients who underwent a repeat procedure (n=26) for symptomatic recurrent arrhythmias after index first-time treatment with single-shot PFA PVI (n=266) from July 2021 to June 2023 were investigated with 3D high-density mapping and ad-hoc re-ablation by radiofrequency or focal PFA. RESULTS: Index indication for PVI was persistent AF in 17 (65%) patients. The mean time to repeat procedure was 292 ± 119 days. Of the 26 patients (104 veins), complete durable PVI was observed in 11/26 (42%) with a durable vein isolation rate of 72/104 (69%). Two patients (8%) had all four veins reconnected. The posterior wall was durably isolated in 4/5 (80%) of the cases. The predominant arrhythmia mechanism was AF in 17/26 (65%) patients and regular atrial tachycardia (AT) in 9/26 (35%). Reconnection was observed 9/26 (35%) in right superior, 11/26 (42%) in right inferior, 7/26 (27%) in left superior, 5/26 (19%) in left inferior, p=0.31 between veins. The gaps were significantly clustered in the right-sided anterior carina compared to other regions (P=0.009). CONCLUSIONS: Durable PVI was observed in less than half of the patients at time of repeat procedure. No significant difference in PV reconnection pattern was observed, but the gap location was preferentially located at the anterior aspects of the right-sided PVs. Predominant recurrence was AF. More data is needed to establish lesion formation and durability and AT circuits after PFA.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ruwald et al. (2023) conducted an observational in Atrial Fibrillation (n=26). Single-shot pulsed field ablation (PFA) was evaluated on Complete durable pulmonary vein isolation (all 4 veins isolated) at time of repeat procedure. Complete durable pulmonary vein isolation was observed in only 42% of patients undergoing a repeat procedure for recurrent arrhythmias after index single-shot pulsed field ablation.