Key result
PFA shows ~63% durable PVI per-vein in patients with arrhythmia recurrence.
Why the study?
Pre-market data showed high rates of PVI durability with a novel multipolar PFA catheter, but post-market data in patients with recurrent arrhythmias were needed.
What is the rate of durable pulmonary vein isolation in patients with recurrent arrhythmia after pulsed-field ablation?
Observational (n=341)
No
What is the rate of durable pulmonary vein isolation in patients with recurrent arrhythmia after pulsed-field ablation?
In patients with recurrent arrhythmia after pulsed-field ablation, durable pulmonary vein isolation was found in 63% of veins, with only minor lesion regression observed.
Answers are grounded in this paper and cite their sources.
Post-market redo data after PFA PVI remain hypothesis-generating; larger prospective studies needed to confirm durability.
BACKGROUND: A novel multipolar pulsed-field ablation (PFA) catheter has recently been introduced for pulmonary vein isolation (PVI). Pre-market data showed high rates for PVI-durability during mandatory remapping studies. OBJECTIVE: To present post-market data in patients with recurrent arrhythmias. METHODS: Consecutive patients undergoing a redo procedure after an index PFA PVI using a bipolar-biphasic PFA system were included. 3-D electro-anatomical maps (3D-EAM) on redo procedure were compared to the 3D-EAM acquired after ablation during the index procedure. PVI durability was assessed on a per-vein and per-patient level and the sites of reconnections were identified. Furthermore, lesion extent around veins with durable isolation was compared to study lesion regression. RESULTS: Of 341 patients treated with a PFA PVI, 29 (8.5%) underwent a left atrial redo ablation due to arrhythmia recurrence. At the end of the index procedure, 110/112 veins (98%, four common ostia) were isolated. On redo procedures performed a median of 6 months after the first ablation, 3D-EAM identified 69/110 (63%) PVs with durable isolation. In 6 (21%) patients, all PVs were durably isolated. Reconnections were more often found on the right-sided veins and on the anterior aspects of the upper veins. Only minor lesion regression was observed between the index and redo procedure (a median of 3 mm (0 - 9.5) on the posterior wall). CONCLUSION: In patients with arrhythmia recurrence after PFA PVI using a first-generation PFA device, durable isolation was observed in 63% of the veins and 21% of the patients showed durable isolation of all previously isolated veins.
No takes yet. Share an insight, caveat, or question.
Kueffer et al. (2023) conducted an observational in Atrial fibrillation (n=341). Pulsed-field ablation (PFA) was evaluated on Durable pulmonary vein isolation at redo procedure (per-vein level). In patients with arrhythmia recurrence after pulsed-field ablation, durable pulmonary vein isolation was observed in 63% of previously isolated veins, with 21% of patients showing durable isolation of all veins.
Synapse has enriched 10 related papers. Consider them for comparative context: