Key result
Single-lead VDD pacemakers in patients with isolated atrioventricular block were associated with a 65% incidence of atrial tachyarrhythmias over a 10-year period.
Why the study?
Does single-lead VDD pacemaker implantation maintain VDD mode survival and atrial sensing in patients with isolated atrioventricular block?
Observational (n=307)
Does single-lead VDD pacemaker implantation maintain VDD mode survival and atrial sensing in patients with isolated atrioventricular block?
While single-lead VDD pacemakers can be applied without serious complications, they are associated with a high long-term incidence of atrial tachyarrhythmias (65%) in patients with isolated AV block.
Answers are grounded in this paper and cite their sources.
High atrial tachyarrhythmia rates may warrant enhanced monitoring with VDD pacemakers; leaves open questions on long-term mode survival in isolated AV block.
AIMS: The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. METHODS AND RESULTS: We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between May 1994 and September 2001. In 39 patients (12.7%), the pacing mode had to be reprogrammed to a single-chamber ventricular pacing mode, mostly due to permanent AT. In 16 of these patients, the atrial sensing safety margin was less than 150%. The atrial sensing safety margin was insufficient, i.e. less than 100% in only seven patients. Although only 12 (3.9%) of the patients had a history of paroxysmal AT at the time of pacemaker implantation, 200 (65%) patients presented with AT during follow-up. The mean AT burden at the last follow-up was 2.5%. CONCLUSION: These data illustrate that single-lead VDD pacemakers can be applied without serious complications in a highly selected group of patients. Our main concern is the development of AT in a large part of our population. Over a 10-year period, two thirds of our patients presented with AT.
No takes yet. Share an insight, caveat, or question.
Zupan et al. (2006) conducted an observational in isolated atrioventricular block (n=307). Single-lead VDD pacemakers was evaluated on development of atrial tachyarrhythmias (AT). Single-lead VDD pacemakers in patients with isolated atrioventricular block were associated with a 65% incidence of atrial tachyarrhythmias over a 10-year period.
Synapse has enriched 10 related papers. Consider them for comparative context: