Key result
Ignoring model discrepancy in cardiac electrophysiology models produces overconfident parameters and inaccurate predictions.
Why the study?
Uncertainty in mathematical model structure or equations itself—termed model discrepancy—remains an under-addressed source of uncertainty in cardiac simulation predictions.
Accounting for model discrepancy using methods like Gaussian processes is crucial for accurate calibration and validation of mechanistic cardiac electrophysiology models.
Requires caution when applying calibrated electrophysiology models to new contexts; leaves open validation of discrepancy-aware methods in future studies.
Uncertainty quantification (UQ) is a vital step in using mathematical models and simulations to take decisions. The field of cardiac simulation has begun to explore and adopt UQ methods to characterize uncertainty in model inputs and how that propagates through to outputs or predictions; examples of this can be seen in the papers of this issue. In this review and perspective piece, we draw attention to an important and under-addressed source of uncertainty in our predictions—that of uncertainty in the model structure or the equations themselves. The difference between imperfect models and reality is termed model discrepancy , and we are often uncertain as to the size and consequences of this discrepancy. Here, we provide two examples of the consequences of discrepancy when calibrating models at the ion channel and action potential scales. Furthermore, we attempt to account for this discrepancy when calibrating and validating an ion channel model using different methods, based on modelling the discrepancy using Gaussian processes and autoregressive-moving-average models, then highlight the advantages and shortcomings of each approach. Finally, suggestions and lines of enquiry for future work are provided. This article is part of the theme issue ‘Uncertainty quantification in cardiac and cardiovascular modelling and simulation’.
No takes yet. Share an insight, caveat, or question.
Lei et al. (2020) conducted a review in Cardiac electrophysiology. Model discrepancy calibration (Gaussian processes and ARMA) vs. Standard calibration ignoring discrepancy (i.i.d. noise) was evaluated. Ignoring model discrepancy during the calibration of mechanistic cardiac electrophysiology models results in overconfident parameter estimates and highly inaccurate predictions in new contexts of use.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: