Answers are grounded in this paper and cite their sources.
Shows effective monitoring of 12 urban wastewater micropollutants, suggesting improved sampling reliability.
• Innovative o-DGT + UHPLC-Q-ToF MS method monitors 12 EU key micropollutants. • Matrix effects minimized via optimized elution and ten-fold dilution procedure. • Five new diffusion coefficients enable average concentration determination in water. • o-DGT outperforms grab sampling for tracer detection and flux estimation. • Combined passive sampling and HRMS allows robust, low-cost, continuous monitoring. This study presents an integrated and innovative approach for monitoring the 12 tracer organic micropollutants introduced in the new Urban Wastewater Directive (PE-CONS 85/1/24) of the European Council. The proposed method combines the Diffusive Gradients in Thin Films (o-DGT) passive sampling with ultra-high-performance liquid chromatography coupled to high-resolution time-of-flight mass spectrometry (UHPLC-Q-ToF MS). The analytical procedure was validated in terms of linearity, accuracy, and limits of quantification (LOQs), which ranged from 0.05 to 0.5 µg L⁻¹ for all compounds, except for hydrochlorothiazide (2 µg L⁻¹). Matrix interferences in o-DGT extracts (comprising agarose diffusive gel, HLB binding phase, and cellulose acetate membrane) exposed in treated wastewater were effectively removed after evaporation and ten-fold dilution, ensuring reliable quantification of target compounds. Following laboratory calibration, with the determination of five new diffusion coefficients, o-DGT devices were deployed at three sites along a river, including the urban wastewater treatment plant (WWTP) discharge channel. The combination of passive sampling and the developed analytical method enabled the detection of all 12 target compounds in WWTP treated waters and revealed an increased micropollutant concentrations in downstream site. Beyond confirming the method robustness and field applicability, o-DGT proved to be more sensitive and reliable than commonly used grab sampling, which failed to quantify certain compounds at low concentration in water. Moreover, o-DGT allowed the estimation of time-weighted average (TWA) concentrations and fluxes, representing a powerful tool for future monitoring of the efficiency of WWTP to remove micropollutant from water.
No takes yet. Share an insight, caveat, or question.
Maria et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: