An algorithm is developed for computing which sensors to add to meet a diagnosis requirement specification concerning fault detectability and fault isolability. The method is based only on the structural information in a model, which means that possibly large and nonlinear differential-algebraic models can be handled in an efficient manner. The approach is exemplified on a model of an industrial valve where the benefits and properties of the method are clearly shown.
No takes yet. Share an insight, caveat, or question.
Krysander et al. (2008) studied this question.