Answers are grounded in this paper and cite their sources.
Examines blood-brain barrier water exchange metrics in healthy volunteers, highlighting model impact and accuracy.
Purpose To evaluate potential modeling paradigms and the impact of relaxation time effects on human blood‐brain barrier (BBB) water exchange measurements using FEXI (BBB‐FEXI), and to quantify the accuracy, precision, and repeatability of BBB‐FEXI exchange rate estimates at 3. Methods Three modeling paradigms were evaluated: (i) the apparent exchange rate (AXR) model; (ii) a two‐compartment model () explicitly representing intra‐ and extravascular signal components, and (iii) a two‐compartment model additionally accounting for finite compartmental and relaxation times (). Each model had three free parameters. Simulations quantified biases introduced by the assumption of infinite relaxation times in the AXR and models, as well as the accuracy and precision of all three models. The scan–rescan repeatability of all paradigms was quantified for the first time in vivo in 10 healthy volunteers (age range 23–52 years; five female). Results The assumption of infinite relaxation times yielded exchange rate errors in simulations up to 42%/14% in the AXR/ models, respectively. Accuracy was highest in the compartmental models; precision was best in the AXR model. Scan–rescan repeatability in vivo was good for all models, with negligible bias and repeatability coefficients in grey matter of , , and . Conclusion Compartmental modelling of BBB‐FEXI signals can provide accurate and repeatable measurements of BBB water exchange; however, relaxation time and partial volume effects may cause model‐dependent biases.
No takes yet. Share an insight, caveat, or question.
Powell et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: