Key result
Second-generation ADV cryoballoon linked to ~18-point higher long-term freedom from AF vs. first-generation balloon.
Why the study?
Does the second-generation ADV cryoballoon improve long-term freedom from atrial fibrillation compared to the first-generation cryoballoon in patients with paroxysmal atrial fibrillation?
Observational (n=120)
No
Does the second-generation ADV cryoballoon improve long-term freedom from atrial fibrillation compared to the first-generation cryoballoon in patients with paroxysmal atrial fibrillation?
The second-generation ADV cryoballoon provides superior long-term rhythm control and shorter procedure times for paroxysmal atrial fibrillation compared to the first-generation device.
Answers are grounded in this paper and cite their sources.
Second-generation cryoballoon was associated with higher long-term AF freedom; leaves open whether randomized trials will confirm superiority.
Introduction. Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. Methods. A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. Results. There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3 ± 16.8 versus 14.2 ± 13.5 min, resp.; p = 0.00016) and longer procedure times as well (153.1 ± 32 versus 102 ± 24.8 min, resp.; p = 0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p = 0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p = 0.61 and 0.57). There were no significant differences in procedural-related complications. Conclusion. The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter.
No takes yet. Share an insight, caveat, or question.
Conti et al. (2016) conducted an observational in Paroxysmal Atrial Fibrillation (PAF) (n=120). Second-generation Arctic Front Advance (ADV) cryoballoon vs. First-generation Arctic Front cryoballoon was evaluated on Long-term freedom from atrial fibrillation (p=0.017). The second-generation ADV cryoballoon significantly increased long-term freedom from atrial fibrillation to 86.7% compared to 68.3% with the first-generation cryoballoon.
Synapse has enriched 10 related papers. Consider them for comparative context: