Key result
Transesophageal Doppler measurement of cardiac output showed a bias of -0.32 L/min compared to thermodilution at a PaCO2 of 40 mmHg, indicating it is less accurate when PaCO2 increases.
Why the study?
Does cardiac output measurement using transesophageal Doppler agree with thermodilution when changing PaCO2 in patients undergoing off-pump coronary artery graft surgery?
RCT (n=30)
random order
Does cardiac output measurement using transesophageal Doppler agree with thermodilution when changing PaCO2 in patients undergoing off-pump coronary artery graft surgery?
Transesophageal Doppler is less accurate than thermodilution for measuring cardiac output when PaCO2 increases, likely because it fails to account for changes in cerebral blood flow.
Answers are grounded in this paper and cite their sources.
Transesophageal Doppler cardiac output requires caution with PaCO2 changes in cardiac surgery; extends evidence of its inaccuracy versus thermodilution.
Cardiac output (CO) determination using transesophageal Doppler is based on the measurement of descending aortic blood flow. Because cerebral blood flow is dependent on PaCO2, an increase in PaCO2 would result in an increase of CO because of the increase in cerebral blood flow and vice versa. We enrolled 30 patients undergoing off-pump coronary artery graft surgery in the study. The CO was determined by both transesophageal Doppler and thermodilution while PaCO2 was maintained at either 30 mmHg or 40 mmHg in random order. The CO by thermodilution was significantly higher at PaCO2 of 40 mmHg (4.17 +/- 0.94 L/min) than at 30 mmHg (3.78 +/- 0.85 L/min). On the other hand, there were no significant differences in CO by transesophageal Doppler: 3.85 +/- 0.76 L/min at PaCO2 of 40 mmHg and 3.77 +/- 0.74 at 30 mmHg. Bland-Altman analysis yielded bias and precision of -0.32 and 0.49 L/min at PaCO2 of 40 mmHg, and -0.01 and 0.34 L/min at 30 mmHg. These results indicate that both methods of CO measurement are in agreement at 30 mmHg of PaCO2, but the thermodilution method provides higher values at 40 mmHg of PaCO2.
No takes yet. Share an insight, caveat, or question.
Sawai et al. (2005) conducted an RCT in off-pump coronary artery graft surgery (n=30). Transesophageal Doppler vs. Thermodilution was evaluated on Cardiac output at PaCO2 of 40 mmHg (bias -0.32 L/min). Transesophageal Doppler measurement of cardiac output showed a bias of -0.32 L/min compared to thermodilution at a PaCO2 of 40 mmHg, indicating it is less accurate when PaCO2 increases.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: