Key result
Overlapping stents for extracranial carotid pathologies resulted in no permanent strokes, stenting-related deaths, or significant (>50%) poststenting stenosis over a mean follow-up of 2.1 years.
Why the study?
Do overlapping stents provide safe and durable outcomes in patients with extracranial carotid artery pathologies?
Observational (n=11)
No
Do overlapping stents provide safe and durable outcomes in patients with extracranial carotid artery pathologies?
Overlapping stents provide a durable and safe treatment option for various extracranial carotid pathologies without causing significant post-stenting stenosis.
May support overlapping carotid stents in select cases; hypothesis-generating and requires prospective validation before practice change.
Various diseases of the carotid artery are treatable by stenting. However, few reports of overlapping carotid stents exist. As a result, the indications, long-term outcomes, and potential complications of this technique remain largely unknown. We therefore present and examine a series of 11 patients treated by this unique stenting method. A retrospective single-institution review was performed for patients in whom overlapping carotid stents were placed. Only patients with imaging follow-up beyond 3 months were included. Of 38 patients who had extracranial carotid artery stents placed, 11 patients fulfilled the inclusion criteria for both overlapping stents and imaging follow-up greater than 3 months (range, 0.4-3 years; mean, 1.3 years). Clinical follow-up ranged between 0.4 and 3.6 years (mean, 2.1 years). Carotid pathology within this cohort included atheromatous stenosis (n = 3), recurrent stenosis following carotid endarterectomy (n = 2) or stenting (n = 1), postirradiation angiitis (n = 1), carotid artery kink created by initial stent placement (n = 2), and both traumatic (n = 1) and neoplastic (n = 1) carotid blowout syndrome. No permanent stroke or stenting-related death occurred. Focal stenosis or intimal hyperplasia resulting in 35% or less luminal narrowing developed in three patients (27%) after tandem stenting. Overlapping stents provide a durable treatment for a variety of extracranial carotid pathologies. Clinically and hemodynamically significant (> 50%) poststenting stenosis or intimal hyperplasia did not occur in this series.
No takes yet. Share an insight, caveat, or question.
Lesley et al. (2004) conducted an observational in Extracranial carotid artery pathology (n=11). Overlapping carotid stents was evaluated on Permanent stroke or stenting-related death. Overlapping stents for extracranial carotid pathologies resulted in no permanent strokes, stenting-related deaths, or significant (>50%) poststenting stenosis over a mean follow-up of 2.1 years.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: