Key result
Oxygen inhalation in adult patients with a Fontan circulation significantly decreased systolic peak kinetic energy from 19.8 to 15.5 μJ/ml (p=0.046) and improved diastolic inflow in some patients.
Why the study?
The study tested acute vasodilator response using 4D flow MRI during oxygen inhalation to assess pulmonary venous return in awake Fontan patients.
Does oxygen inhalation improve cardiac filling and kinetic energy parameters measured by 4D Flow MRI in adult patients with a Fontan circulation?
Does oxygen inhalation improve cardiac filling and kinetic energy parameters measured by 4D Flow MRI in adult patients with a Fontan circulation?
Absolute Event Rate: 15.5% vs 19.8%
p-value: p=0.046
Non-invasive 4D Flow MRI during oxygen inhalation is feasible for acute vasodilator response testing in Fontan patients, revealing improved cardiac filling and efficiency in a subset of responders.
Supports 4D Flow MRI for acute vasodilator testing in Fontan patients; hypothesis-generating and should not yet change practice.
BACKGROUND: testing of acute vasodilator response using four-dimensional (D) flow MRI during oxygen inhalation. MATERIALS AND METHODS: Six patients with well-functioning Fontan circulations were prospectively recruited and underwent cardiac MRI. Ventricular anatomical imaging and 4D Flow MRI were acquired at baseline and during inhalation of oxygen. Data were compared with six age-matched healthy volunteers with 4D Flow MRI scans acquired at baseline. RESULTS: All six patients tolerated the MRI scan well. The dominant ventricle had a left ventricular morphology in all cases. On 4D Flow MRI assessment, two patients (Patients 2 and 6) showed improved cardiac filling with improved preload during oxygen administration, increased mitral inflow, increased maximum E-wave kinetic energy, and decreased systolic peak kinetic energy. Patient 1 showed improved preload only. Patient 5 showed no change, and patient 3 had equivocal results. Patient 4, however, showed a decrease in preload and cardiac filling/function with oxygen. DISCUSSION: Using oxygen as a pulmonary vasodilator to assess increased pulmonary venous return as a marker for positive acute vasodilator response would provide pre-treatment assessment in a more physiological state - the awake patient. This proof-of-concept study showed that it is well tolerated and has shown changes in some stable patients with a Fontan circulation.
No takes yet. Share an insight, caveat, or question.
McConnell et al. (2022) studied Fontan circulation (n=12). Oxygen inhalation vs. Baseline (room air) was evaluated on Systolic peak kinetic energy (p=0.046). Oxygen inhalation in adult patients with a Fontan circulation significantly decreased systolic peak kinetic energy from 19.8 to 15.5 μJ/ml (p=0.046) and improved diastolic inflow in some patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: