Key result
A deep neural oracle-based architecture achieved a compression factor of 2.67 for ECG or EEG signals with a complexity of only 24 signed sums per processed sample.
Answers are grounded in this paper and cite their sources.
A novel deep neural oracle architecture enables efficient compressed sensing and recovery of ECG/EEG signals with very low computational complexity.
The recovery of sparse signals given their linear mapping on lower-dimensional spaces can be partitioned into a support estimation phase and a coefficient estimation phase. We propose to estimate the support with an oracle based on a deep neural network trained jointly with the linear mapping at the encoder. The divination of the oracle is then used to estimate the coefficients by pseudo-inversion. This architecture allows the definition of an encoding-decoding scheme with state-of-the-art recovery capabilities when applied to biological signals such as ECG and EEG, thus allowing extremely low-complex encoders. As an additional feature, oracle-based recovery is able to self-assess, by indicating with remarkable accuracy chunks of signals that may have been reconstructed with a non-satisfactory quality. This self-assessment capability is unique in the CS literature and paves the way for further improvements depending on the requirements of the specific application. As an example, our scheme is able to satisfyingly compress by a factor of 2.67 an ECG or EEG signal with a complexity equivalent to only 24 signed sums per processed sample.
No takes yet. Share an insight, caveat, or question.
Mangia et al. (2019) studied this question. Deep neural oracle-based compressed sensing architecture was evaluated on Signal compression and recovery. A deep neural oracle-based architecture achieved a compression factor of 2.67 for ECG or EEG signals with a complexity of only 24 signed sums per processed sample.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: