Key result
0-dimensional hemodynamic simulation yields a low-to-moderate 0.68 AUC for identifying stroke-vulnerable brain areas.
Why the study?
Does a 0-dimensional simulation model accurately identify brain areas vulnerable to stroke compared to DSC-MRI in patients with intracranial atherosclerotic disease?
Observational (n=68)
Blinded to clinical information
No
Does a 0-dimensional simulation model accurately identify brain areas vulnerable to stroke compared to DSC-MRI in patients with intracranial atherosclerotic disease?
A 0-dimensional simulation model of cerebral hemodynamics showed low-to-moderate accuracy in identifying stroke-vulnerable brain areas compared to DSC-MRI in patients with intracranial atherosclerotic disease.
Answers are grounded in this paper and cite their sources.
Does not support clinical adoption of this model; leaves open whether refined simulations can aid stroke risk stratification in ICAD.
Intracranial atherosclerotic disease (ICAD) poses a significant risk of subsequent stroke but current prevention strategies are limited. Mechanistic simulations of brain hemodynamics offer an alternative precision medicine approach by utilising individual patient characteristics. For clinical use, however, current simulation frameworks have insufficient validation. In this study, we performed the first quantitative validation of a simulation-based precision medicine framework to assess cerebral hemodynamics in patients with ICAD against clinical standard perfusion imaging. In a retrospective analysis, we used a 0-dimensional simulation model to detect brain areas that are hemodynamically vulnerable to subsequent stroke. The main outcome measures were sensitivity, specificity, and area under the receiver operating characteristics curve (ROC AUC) of the simulation to identify brain areas vulnerable to subsequent stroke as defined by quantitative measurements of relative mean transit time (relMTT) from dynamic susceptibility contrast MRI (DSC-MRI). In 68 subjects with unilateral stenosis >70% of the internal carotid artery (ICA) or middle cerebral artery (MCA), the sensitivity and specificity of the simulation were 0.65 and 0.67, respectively. The ROC AUC was 0.68. The low-to-moderate accuracy of the simulation may be attributed to assumptions of Newtonian blood flow, rigid vessel walls, and the use of time-of-flight MRI for geometric representation of subject vasculature. Future simulation approaches should focus on integrating additional patient data, increasing accessibility of precision medicine tools to clinicians, addressing disease burden disparities amongst different populations, and quantifying patient benefit. Our results underscore the need for further improvement of mechanistic simulations of brain hemodynamics to foster the translation of the technology to clinical practice.
No takes yet. Share an insight, caveat, or question.
Behland et al. (2023) conducted an observational in Intracranial atherosclerotic disease (ICAD) (n=68). 0-dimensional simulation model of brain hemodynamics vs. Dynamic susceptibility contrast MRI (DSC-MRI) was evaluated on Diagnostic accuracy (sensitivity, specificity, and ROC AUC) to identify brain areas vulnerable to subsequent stroke (Sensitivity 0.65, Specificity 0.67, ROC AUC 0.68). A 0-dimensional simulation model of brain hemodynamics showed low-to-moderate accuracy in identifying stroke-vulnerable brain areas in patients with intracranial atherosclerotic disease, yielding a sensitivity of 0.65, specificity of 0.67, and ROC AUC of 0.68.
Synapse has enriched 10 related papers. Consider them for comparative context: