Answers are grounded in this paper and cite their sources.
Compares core temperature measurements in firefighters, indicating limited accuracy of heart rate estimation.
Background: Firefighters may experience high environmental temperatures or carry out intensive physical tasks, or both, which leads to increased core body temperature and risk of fatalities. Hence there is a need to remotely and non-invasively monitor core body temperature. Methods: Estimated (heart rate algorithm) and actual core body temperature (ingested telemetric pill) measures were collected simultaneously for comparison during training exercises on 44 firefighter volunteers. Results: Prediction of core body temperature varied, with no specific identifiable pattern between the algorithm values and directly measured body core temperatures. Group agreement of Lin's Concordance of 0.74 (95% Upper 0.75, lower CI 0.73), was deemed poor. Conclusion: From individual agreement data Lin's Concordance was variable (Min 0.11, CI 0.13-0.01; Max 0.83, CI 0.86-0.80), indicating that the heart rate algorithm approach was not suitable for core body temperature monitoring in this population group, especially at the higher more critical core body temperatures seen.
No takes yet. Share an insight, caveat, or question.
Pearson et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: