Key result
An algorithm using optimized tunable-Q wavelet transform and dead-zone quantizer achieved significant ECG data compression with an average compression ratio of 22.42 and PRD of 4.52%.
Why the study?
ECG recording generates large amounts of digitized data, creating a need to reduce data size due to memory constraints in ambulatory and telemedicine systems.
Answers are grounded in this paper and cite their sources.
The proposed algorithm using optimized TQWT and dead-zone quantizer achieves significant ECG data compression with acceptable signal distortion, which may be useful for ambulatory and telemedicine systems.
In the biomedical field, electrocardiogram (ECG) recording produces a large amount of data, which are stored in a digitized format for monitoring and diagnosis purposes. In this regard, it is essential to reduce data size due to memory constraints in ambulatory and tel-e-medicine systems. This paper proposes an algorithm using optimized tunable-Q wavelet transform (TQWT) to reduce the memory requirement. It has the flexibility to tune its parameters to obtain the desired compression. For optimizing the parameters of TQWT, nature-inspired algorithm ant colony optimization (ACO) is used. The compression is achieved by using a dead-zone quantizer (DZQ) and run-length encoding (RLE). Results illustrate that significant compression has been achieved at the cost of acceptable distortion in the signal quality. The performance of the proposed technique is evaluated using percentage-root-mean square difference (PRD), compression ratio (CR), and quality score (QS). The average value obtained of CR, PRD, and QS are given as 22.42, 4.52%, and 6.05, respectively.
No takes yet. Share an insight, caveat, or question.
Pal et al. (2021) studied Electrocardiogram (ECG) compression. Optimized tunable-Q wavelet transform (TQWT) with dead-zone quantizer (DZQ) was evaluated on Compression ratio (CR), percentage-root-mean square difference (PRD), and quality score (QS). An algorithm using optimized tunable-Q wavelet transform and dead-zone quantizer achieved significant ECG data compression with an average compression ratio of 22.42 and PRD of 4.52%.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: