Key result
The proposed ECG signal compression algorithm using discrete wavelet transform exhibited better compression performance than existing techniques while maintaining diagnostic quality.
Why the study?
Distortion of reconstructed ECG signals depends on the type of mother wavelet used for decomposition, requiring selection of an appropriate mother wavelet to produce minimal distortion.
Does the proposed ECG signal compression algorithm improve compression performance with minimal distortion compared to existing techniques?
Does the proposed ECG signal compression algorithm improve compression performance with minimal distortion compared to existing techniques?
Answers are grounded in this paper and cite their sources.
The proposed ECG signal compression algorithm using discrete wavelet transform achieves better compression performance with minimal distortion compared to existing techniques.
This study presents a diagnostic quality assured electrocardiogram (ECG) signal compression algorithm which uses discrete wavelet transform with the selection of appropriate mother wavelet. Since distortion of reconstructed ECG signal depends on the type of mother wavelet used for decomposition. Therefore, appropriate mother wavelet is selected first which produces minimal distortion. Small valued wavelet transform coefficients are discarded using dead‐zone quantisation. Further integer conversion of coefficients is performed to improve compression at the cost of very less error. The processed transform coefficients obtained at this stage contain approximate coefficients and detail coefficients, where approximate coefficients consist very less repetition of data instances while detail coefficients are much repetitive. The repetition of detail coefficients is exploited by run–length encoding which represents the data as run and length. Compression performance of the proposed algorithm is evaluated using single‐channel ECG records taken from the Massachusetts Institute of Technology‐Beth Israel Hospital (MIT‐BIH) arrhythmia database, MIT‐BIH ECG compression test database and Physikalisch‐Technische Bundesanstalt (PTB) diagnostic ECG database. Compression results exhibit better performance than other existing techniques. Subjective evaluation of reconstructed ECG signals is also performed which ensures effective working of the proposed algorithm on the different morphology of ECG signals.
No takes yet. Share an insight, caveat, or question.
Jha et al. (2019) studied Electrocardiogram (ECG) signal compression. Diagnostic quality assured ECG signal compression algorithm using discrete wavelet transform vs. Other existing techniques was evaluated on Compression performance and subjective evaluation of reconstructed ECG signals. The proposed ECG signal compression algorithm using discrete wavelet transform exhibited better compression performance than existing techniques while maintaining diagnostic quality.
Synapse has enriched 10 related papers. Consider them for comparative context: