Key result
Left-sided thoracoscopic hybrid ablation yields ~67% freedom from arrhythmia recurrence at 24 months in AF.
Why the study?
While studies have reported on bilateral thoracoscopic hybrid ablation for AF, data on a unilateral left-sided approach are scarce.
Does unilateral left-sided hybrid ablation provide effective rhythm control and safety in patients with atrial fibrillation?
Cohort (n=119)
No
Does unilateral left-sided hybrid ablation provide effective rhythm control and safety in patients with atrial fibrillation?
Unilateral left-sided hybrid ablation is an efficacious and safe approach for treating paroxysmal and persistent atrial fibrillation, achieving 67% freedom from recurrence at 24 months.
Supports unilateral left-sided hybrid ablation for AF rhythm control; leaves open confirmation of efficacy and safety in randomized trials.
BACKGROUND: Hybrid ablation (HA) of atrial fibrillation (AF) combines minimally invasive thoracoscopic epicardial ablation with transvenous endocardial electrophysiologic validation and touch-up of incomplete epicardial lesions if needed. While studies have reported on a bilateral thoracoscopic HA approach, data on a unilateral left-sided approach are scarce. AIM: To evaluate the efficacy and safety of a unilateral left-sided thoracoscopic approach. METHODS: Retrospective analysis of a prospectively gathered cohort of all consecutive patients undergoing a unilateral left-sided HA for AF between 2015 and 2018 in the Maastricht University Medical Centre. In all patients, a unilateral left-sided HA consisting of pulmonary vein (PV) isolation, posterior left atrial (LA) wall isolation, and LA appendage exclusion was attempted. Epicardial (n = 59) and/or endocardial validation (n = 81) was performed and endocardial touch-up was performed in 33 patients. Major peri-operative complications occurred in 5% of all patients. After 12 and 24 months, the probability of being free from supraventricular tachyarrhythmia recurrence was 80% [73-87] and 67% [58-76], respectively, when allowing antiarrhythmic drugs. CONCLUSION: Unilateral left-sided hybrid AF ablation is an efficacious and safe approach to treat patients with paroxysmal and (longstanding) persistent AF. Future studies should compare a unilateral with a bilateral approach to determine whether a left-sided approach is as efficacious as a bilateral approach and allows for less complications.
No takes yet. Share an insight, caveat, or question.
Heijden et al. (2022) conducted a cohort in Atrial Fibrillation (n=119). Unilateral left-sided thoracoscopic hybrid ablation was evaluated on Freedom from any supraventricular tachyarrhythmia ≥30 s until 24 months of follow-up (allowing antiarrhythmic drugs) (95% CI 58-76). Unilateral left-sided thoracoscopic hybrid ablation achieved a 67% probability of freedom from supraventricular tachyarrhythmia recurrence at 24 months in patients with atrial fibrillation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: