Key result
The proposed Kalman-based spectro-temporal ECG analysis combined with a Dense18+ convolutional neural network achieved an overall F1 score of 80.2% for atrial fibrillation detection.
Why the study?
Does Kalman-based spectro-temporal ECG analysis using deep convolutional networks improve atrial fibrillation detection in single-lead ECG recordings?
Does Kalman-based spectro-temporal ECG analysis using deep convolutional networks improve atrial fibrillation detection in single-lead ECG recordings?
Answers are grounded in this paper and cite their sources.
A novel Kalman-based spectro-temporal ECG analysis combined with a DenseNet classifier achieves high accuracy (F1 score 80.2%) for automated atrial fibrillation detection from short single-lead ECGs.
In this article, we propose a novel ECG classification framework for atrial fibrillation (AF) detection using spectro-temporal representation (i.e., time varying spectrum) and deep convolutional networks. In the first step we use a Bayesian spectro-temporal representation based on the estimation of time-varying coefficients of Fourier series using Kalman filter and smoother. Next, we derive an alternative model based on a stochastic oscillator differential equation to accelerate the estimation of the spectro-temporal representation in lengthy signals. Finally, after comparative evaluations of different convolutional architectures, we propose an efficient deep convolutional neural network to classify the 2D spectro-temporal ECG data. The ECG spectro-temporal data are classified into four different classes: AF, non-AF normal rhythm (Normal), non-AF abnormal rhythm (Other), and noisy segments (Noisy). The performance of the proposed methods is evaluated and scored with the PhysioNet/Computing in Cardiology (CinC) 2017 dataset. The experimental results show that the proposed method achieves the overall F1 score of 80.2%, which is in line with the state-of-the-art algorithms.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2020) studied Atrial Fibrillation (n=8,528). Kalman-based Spectro-Temporal ECG Analysis with Deep Convolutional Networks vs. Standard time-frequency analysis methods (STFT, CWT, BurgAR) and other classifiers was evaluated on Overall F1 score for 4-class ECG classification. The proposed Kalman-based spectro-temporal ECG analysis combined with a Dense18+ convolutional neural network achieved an overall F1 score of 80.2% for atrial fibrillation detection.
Synapse has enriched 10 related papers. Consider them for comparative context: