Demonstrates improved stability in grid-connected inverters, suggesting a new design method.
The stability of grid-connected voltage-source inverters (VSI) is deteriorated in a weak grid due to the interaction between the increasing grid impedance and the inherent inverter impedance. To improve the stability of LCL-filtered VSI, an impedance-phase reshaping method is proposed in paper. With this output current feedback compensator, the phase margin at the impedance intersection can be improved dramatically. A straightforward parameter design method is also introduced to simplify the design procedure. Simulation and experimental results valid the effectiveness of the proposed the method and design methodology.
No takes yet. Share an insight, caveat, or question.
Du et al. (2017) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: