Key result
A 1-minute active orthostatic test provoked maximal low-frequency power surges and minimal central frequency falls that were different from control means.
Why the study?
Does a 1-min active orthostatic test alter the time-courses of central frequencies and powers of low-frequency components of RR intervals and blood pressure in healthy subjects?
Observational (n=25)
Does a 1-min active orthostatic test alter the time-courses of central frequencies and powers of low-frequency components of RR intervals and blood pressure in healthy subjects?
The patterned responses of low-frequency components of RR and blood pressure during active orthostatic testing suggest that central frequencies are reliable quantitative measures of sympathetic activation.
Answers are grounded in this paper and cite their sources.
Does not support clinical adoption of orthostatic testing; hypothesis-generating for central frequencies as sympathetic markers.
In 25 healthy subjects we assessed the effects provoked by 1-min of active orthostatic test (AOT) on time-courses of central frequencies and powers of low frequency components (<inf>CF</inf>LF, <inf>P</inf>LF) of RR (<inf>CF</inf>LF<inf>RR</inf>, <inf>P</inf>LF<inf>RR</inf>), systolic (<inf>CF</inf>LF<inf>SP</inf>, <inf>P</inf>LF<inf>SP</inf>) and diastolic (<inf>CF</inf>LF<inf>DP</inf>, <inf>P</inf>LF<inf>DP</inf>) pressures, estimated by a time-frequency distribution. Ensemble averages of the three <inf>P</inf>LF-<inf>CF</inf>LF pairs dynamics depicted an initial sudden change (ISC), followed by a recovery change (RC) and a final sudden change (FSC). The rapid changes were upwards for <inf>P</inf>LF and downwards for <inf>CF</inf>LF. Means of the maximal <inf>P</inf>LF surges and of minimal <inf>CF</inf>LF falls were greater and smaller (<tex>$p < 0.01$</tex>) than their respective control means. Mean correlations of the three <inf>P</inf>LF-<inf>CF</inf>LF relations ranged from <tex>- 0.95+ 0.05\ to\ -0.97± 0.04</tex> in ISC, <tex>-0.86± 0.13\ to\ -0.87± 0.15</tex> in R C and <tex>-0.30± 0.59</tex> to <tex>-0.41± 0.63</tex> in FSC. In all stages, means of <inf>CF</inf>LF<inf>RR</inf> were greater (<tex>$p < 0.04$</tex>) than those of <inf>CF</inf>LF<inf>DP</inf>. That the patterned responses of the three <inf>P</inf>LF-<inf>CF</inf>LF pairs time-courses present rapid initial and final changes, upstrokes for <inf>P</inf>LF and falls for <inf>CF</inf>LF, significantly inversely correlated, and the greater level of <inf>CF</inf>LF<inf>RR</inf> than <inf>CF</inf>LF<inf>DP</inf>, refine the time-course of cardiovascular sympathetic activation in AOT, possibly non-uniform, and suggest that <inf>CF</inf>LF are trustable quantitative sympathetic measures, with some specificity, <inf>CF</inf>LF<inf>RR</inf> for the cardiac and <inf>CF</inf>LF<inf>DP</inf> for the vasomotor one.
No takes yet. Share an insight, caveat, or question.
Carrasco‐Sosa et al. (2021) conducted an observational in Healthy (n=25). Active orthostatic test (AOT) vs. Control was evaluated on Time-courses of central frequencies and powers of low frequency components of RR intervals, systolic and diastolic pressures (p=< 0.01). A 1-minute active orthostatic test provoked maximal low-frequency power surges and minimal central frequency falls that were different from control means.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: