Aiming to suppress DC-link voltage harmonics of dual PWM rectifiers with DC-link parallel connection in electrical traction AC drive system, the operating principle of single-phase PWM rectifier is firstly introduced in this paper. Then the characteristics of DC-link voltage harmonics in the steady-state are derived, and the effect between carrier phase-shifting technology and DC link voltage harmonics of the dual PWM rectifiers is analyzed in detail. Theoretical analysis shows that the high order harmonics of DC-link voltage are mainly distributed around the twice switching frequency, and the carrier phase-shifting technology can suppress the DC-link voltage harmonic coefficient through reducing these high order harmonics. Finally, the performances of carrier phase-shifting and non-carrier phase-shifting technology are verified in computer simulation and hardware-in-the-loop(HIL) experiment system tests, respectively. And both of the simulation and experimental results verify the validity and effectiveness of theoretical analysis.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2012) studied this question.