Key result
Incorporating intrinsic electrophysiological heterogeneity in a rabbit ventricular model facilitated arrhythmia initiation but played little functional role during sustained rapid arrhythmias.
Population
Biventricular rabbit computational model
Comparison
Incorporation of transmural and apicobasal… vs Equivalent homogeneous model
Design
Preclinical
Authors
Loading...
Questions need to include electrophysiological heterogeneity in models of sustained arrhythmias; leaves open its role during initiation.
Intrinsic electrophysiological heterogeneity is important for arrhythmia initiation but plays little functional role during sustained arrhythmia dynamics in healthy ventricles, questioning the need for its inclusion in computational models of rapid arrhythmias.
Bishop et al. (2013) studied Arrhythmias. Transmural and apicobasal action potential duration (APD) heterogeneity vs. Equivalent homogeneous model was evaluated on Arrhythmia initiation and sustained reentrant behavior. Incorporating intrinsic electrophysiological heterogeneity in a rabbit ventricular model facilitated arrhythmia initiation but played little functional role during sustained rapid arrhythmias.