Key result
A tinyML-based solution for continuous blood pressure estimation on edge devices achieved comparable results to server-based solutions, meeting the British Hypertension Society standard for grade B.
Why the study?
Can a tinyML-based solution on edge devices accurately estimate continuous blood pressure using ECG and PPG sensors compared to server-based solutions?
Can a tinyML-based solution on edge devices accurately estimate continuous blood pressure using ECG and PPG sensors compared to server-based solutions?
A novel tinyML-based edge computing solution can accurately estimate continuous blood pressure from ECG and PPG signals without relying on cloud infrastructure.
May support edge-based BP monitoring; leaves open prospective clinical validation before adoption.
We propose a solution that deploys Machine Learning (ML) techniques on resource-constrained edge devices (tinyMl)for the healthcare domain. In particular, we construct a complete end-to-end prototyped system that conducts ML inference with various ML techniques on microcontroller unit (MCU)-powered edge devices to predict blood-pressure-related vital metrics such as systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressures using electrocardiogram (ECG) and photoplethysmogram (PPG) sensors. The proposed solution is trained and tested using over 500 hours of 12, 000 real intensive care unit data instances. Despite running on an extremely limited computation, power and memory budget, the proposed solution achieves comparable results to server-based state-of-the-art solutions. Furthermore, it meets the British Hypertension Society (BHS) standard for grade B (C in extremely-constrained devices). This is achieved by careful investigation of the correlation between a wide-set of ECG and PPG features and BP. Afterwards, we compress the ML inference models by only incorporating the minimal features that meet i) the edge constraints from one side, and ii) the standard's acceptable accuracy from the other side. Unlike existing solutions, the inference is entirely conducted on MCU-based edge devices without depending on any cloud-based infrastructure. Hence, the proposed solution improves robustness, accessibility, reliability, security, as well as data privacy.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2022) studied Blood pressure estimation (n=12,000). tinyML-based continuous blood pressure estimation on MCU-powered edge devices vs. Server-based state-of-the-art solutions was evaluated on Blood pressure estimation accuracy (SBP, DBP, MAP) meeting British Hypertension Society (BHS) standard. A tinyML-based solution for continuous blood pressure estimation on edge devices achieved comparable results to server-based solutions, meeting the British Hypertension Society standard for grade B.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: