Key result
A portable, IoT-based multi-signal acquisition system was developed to simultaneously monitor ECG, PPG, SpO2, and PCG, with blood pressure estimation errors falling within standard allowable limits.
Why the study?
Does a portable multi-parameter biomedical signal acquisition system using IoT accurately estimate blood pressure and heart rate compared to a standard digital monitor?
Does a portable multi-parameter biomedical signal acquisition system using IoT accurately estimate blood pressure and heart rate compared to a standard digital monitor?
Answers are grounded in this paper and cite their sources.
A newly developed portable IoT-based multi-signal acquisition system can estimate blood pressure with an error margin acceptable by AAMI standards.
Remarkable technological developments in recent years have opened up new possibilities of improving public health care system. Developments in computing, signal processing and communication technologies have resulted in new diagnostic instruments with better precision and connectivity with computing machines, communication gadgets and databases. Among the various vital biomedical signals that can be collected noninvasively, ECG, PPG, SpO2 and PCG collected simultaneously, can help in examining electrical (ECG) and mechanical (PCG) functioning of heart, efficiency of lungs (SpO2) and condition of arteries (PPG). This promises to give a composite overview of the whole cardiovascular system non-invasively. In this paper a portable multi-parameter, non-invasive biomedical signal acquisition system (which can monitor, store and communicate the above mentioned four biomedical signals) is developed for regular telemonitoring of patients especially with cardiovascular complaints. The gathered physiological data can be sent to the monitoring station and depending on the condition of the patient, further instructions can be issued from there to assist doctors in early diagnosis of crucial symptoms.
No takes yet. Share an insight, caveat, or question.
V. Radhamani (2017) studied Cardiovascular diseases. Multi-Signal Acquisition System using IoT vs. OMRON digital BP monitor was evaluated on Accuracy of BP and HR extraction (Mean Absolute Error and Error Standard Deviation). A portable, IoT-based multi-signal acquisition system was developed to simultaneously monitor ECG, PPG, SpO2, and PCG, with blood pressure estimation errors falling within standard allowable limits.
Synapse has enriched 10 related papers. Consider them for comparative context: