Key result
UR-CarA-Net achieves ~92% accuracy for automated carotid artery segmentation on black blood MRI.
Answers are grounded in this paper and cite their sources.
UR-CarA-Net provides accurate, fully automated carotid artery segmentation on black blood MRI, which may facilitate robust, large-scale plaque characterization across different scanners.
We present a fully automated method for carotid artery (CA) outer wall segmentation in black blood MRI using partially annotated data and compare it to the state-of-the-art reference model. Our model was trained and tested on multicentric data of patients (106 and 23 patients, respectively) with a carotid plaque and was validated on different MR sequences (24 patients) as well as data that were acquired with MRI systems of a different vendor (34 patients). A 3D nnU-Net was trained on pre-contrast T1w turbo spin echo (TSE) MR images. A CA centerline sliding window approach was chosen to refine the nnU-Net segmentation using an additionally trained 2D U-Net to increase agreement with manual annotations. To improve segmentation performance in areas with semantically and visually challenging voxels, Monte-Carlo dropout was used. To increase generalizability, data were augmented with intensity transformations. Our method achieves state-of-the-art results yielding a Dice similarity coefficient (DSC) of 91.7% (interquartile range (IQR) 3.3%) and volumetric intraclass correlation (ICC) with ground truth of 0.90 on the development domain data and a DSC of 91.1% (IQR 7.2%) and volumetric ICC with ground truth of 0.83 on the external domain data outperforming top-ranked methods for open-source CA segmentation. The uncertainty-based approach increases the interpretability of the proposed method by providing an uncertainty map together with the segmentation.
No takes yet. Share an insight, caveat, or question.
Lavrova et al. (2023) studied Carotid plaque with mild to moderate stenosis (n=187). UR-CarA-Net (automated segmentation framework) vs. Manual ground-truth annotations and baseline nnU-Net was evaluated on Dice similarity coefficient (DSC) for automated carotid artery segmentation. The UR-CarA-Net model achieved highly accurate automated carotid artery segmentation, yielding a Dice similarity coefficient of 91.7% and volumetric intraclass correlation of 0.90 on development domain data.
Synapse has enriched 10 related papers. Consider them for comparative context: