Key result
OUES strongly correlates with VO2max with an r of ~0.94 to estimate cardiorespiratory functional reserve.
Why the study?
Does the oxygen uptake efficiency slope (OUES) provide a reliable submaximal estimation of cardiorespiratory functional reserve compared to VO2max?
Observational (n=144)
Does the oxygen uptake efficiency slope (OUES) provide a reliable submaximal estimation of cardiorespiratory functional reserve compared to VO2max?
OUES provides an objective, effort-independent estimation of cardiorespiratory functional reserve that correlates strongly with VO2max.
OBJECTIVES: We investigated the usefulness of a new variable, oxygen uptake efficiency slope (OUES), as a submaximal measure of cardiorespiratory functional reserve. The OUES is derived from the relation between oxygen uptake (Vo2 [ml/min]) and minute ventilation (VE [liters/min]) during incremental exercise and is determined by VO2 = a log VE + b, where a = OUES, which shows the effectiveness of Vo2. BACKGROUND: Maximal oxygen uptake (VO2max) is effort dependent. There is no standard submaximal measurement of cardiorespiratory reserve that provides generally acceptable results. METHODS: Exercise tests, following a standard Bruce protocol, were performed on a treadmill by 108 patients with heart disease and 36 normal volunteers. Expired gas was continuously analyzed. The OUES was calculated from data of the first 75%, 90% and 100% of exercise duration. We also determined the following submaximal variables: the ventilatory anaerobic threshold (VAT), the slope of the regression line of the minute ventilation-carbon dioxide production relation (VE-VCO2 slope) and the extrapolated maximal oxygen consumption (EMOC). We analyzed the relation of OUES and other submaximal variables against VO2max and examined the effects of submaximal exercise on OUES. RESULTS: The correlation coefficient of the logarithmic curve-fitting model was 0.978 +/- 0.016 (mean +/- SD). The OUES and VO2max had a significant correlation (r = 0.941, p < 0.0001). The correlation between VO2max and OUES was stronger than that between VO2max and VAT, the VE-VCO2 slope or EMOC. The OUES values for 100% and 90% of exercise were not different from each other (at an alpha value of 0.05 and treatment effect of 170, the power of the test [1-beta] was 0.90); OUES for 75% of exercise was slightly lower (3.5%). CONCLUSIONS: Our results suggest that OUES may provide an objective, effort-independent estimation of cardiorespiratory functional reserve that is related both to pulmonary dead space and to metabolic acidosis.
No takes yet. Share an insight, caveat, or question.
Baba et al. (1996) conducted an observational in Heart disease (n=144). Oxygen uptake efficiency slope (OUES) vs. Other submaximal variables (VAT, VE-VCO2 slope, EMOC) was evaluated on Correlation with maximal oxygen uptake (VO2max) (r = 0.941, p=<0.0001). The oxygen uptake efficiency slope (OUES) strongly correlated with maximal oxygen uptake (r = 0.941, p < 0.0001), providing an objective estimation of cardiorespiratory functional reserve.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: