Key result
Para-Hisian pacing reveals mixed ventriculo-atrial conduction via an accessory pathway and fast AV node.
Why the study?
The mechanism underlying a contradictory response of prolonged stimulus-A interval during a wider captured beat on para-Hisian pacing in a patient with suspected accessory pathway conduction was investigated.
Case Report (n=1)
This case highlights that a mixed or fused VA conduction during para-Hisian pacing can occur in the presence of a non-decremental accessory pathway if AV nodal conduction is fast, mimicking a nodal response.
Answers are grounded in this paper and cite their sources.
Requires caution interpreting para-Hisian pacing with fast AV nodal conduction; hypothesis-generating for mixed VA responses in accessory pathway cases.
A 24-year-old man underwent an electrophysiology study for a supraventricular tachycardia with no baseline pre-excitation. A short RP narrow QRS tachycardia with positive HV and central atrial activation was induced with atrial extrastimuli (AES). It was ill-sustained despite isoprenaline. Hence, no maneuvers in tachycardia could be performed. Ventriculo-atrial (VA) conduction during ventricular extrastimuli (VES) was concentric and nondecremental (PCS earliest) until VA block (Figure 1). Differential pacing from RV apex versus RV base consistently favored VA conduction via an accessory pathway (AP) but Para–Hisian Pacing maneuver (PHP) suggested prolongation of VA/Stimulus-A electrogram (SA) time during wider Vc beat (Figure 2). What is the mechanism of this contradictory response during PHP maneuver in this case? Figure 2A shows the electrogram before starting of para-Hisian pacing from His-D bipole. The Figure 2B shows PHP @ 550 ms of pacing cycle length (PCL) and the second beat is wider suggestive of ventricular capture which has longer VA in His and CS poles. Absence of isoelectric interval in the narrower beat excluded pure his capture (one of the common fallacies during PHP). So, the wider VA during the broader QRS complex appears as a nodal response at first glance. However, when looked carefully the atrial activation sequence among various catheters is noted to be different between these two beats. The HB-D and His-P have “A-EGM” earlier than PCS during H+Vc but later than PCS in the next Vc beat. This observation clearly tells that activation of atrium happened via mixed conduction over both AP and AV node (AVN). A coincidental premature atrial complex (PAC) [ another fallacy of PHP] was excluded as this phenomenon happened reproducibly. Now one interesting question is during the PHP which part of atria got activated via AP during fused conduction? We expected that the site activated via AP should have a fixed SA, at least locally, as myocardium is captured in both the beats. In our case, we did not have any local EGM with fixed SA. This means no single local site (having catheters in place), was activated via AP in both the beats. The His signal is well seen much after V-EGM in RB-D in the second beat confirming exclusive myocardial capture (Vc) (Figure 3). The local “A-EGM” in His and RB regions are activated via node during both beats as the HA interval remained constant (70 ms). Understandably, it demonstrates a nodal response if analyzed locally (the upper half of the image above dotted line) (Figure 3). But there is a 46 ms prolongation of SA and HA interval in His-D. The electrograms in the CS make it more interesting (lower half). In the second beat, the conduction is certainly via AP as the “A-EGM” in proximal CS (PCS) is earlier than His (the VA interval unlikely for a slow pathway conduction, VA time in PCS = 105 ms). Now, the VAC in the first beat near PCS could be either via AP or via AV node (AVN) as discussed below: (a) If the VAC in the first beat is via AP: the reason for 25 ms SA prolongation in PCS could be a RA-LV connection (posteroseptal AP). In the first beat with His capture, the LV myocardium would have been activated early but during myocardial capture (V) the LV myocardium was activated trans-septally before the AP could conduct retrogradely leading to the SA prolongation of 25 ms. (b) Alternative option is a brisk AV node conduction in the first beat (faster than the AP conduction). In the second beat when the HB was not directly captured, the AV nodal conduction became slower than that of AP which could manifest itself during the VA conduction. The electrograms prove that the second option (b) is correct. Had it been the first option (a), the local VA in PCS would have been fixed in both beats which is not the case here. The local VA at PCS shows 0 ms in 1st beat but 20 ms in second. Additionally, in the case of (a) the local S-V would be variable. In this case, local S-V in CS was constant (75 ms in PCS). The AP was mapped for an early “A-EGM,” during V pacing and also during ill-sustained tachycardia beats and ablation was successful on right postero-septal endocardium just near the upper lip of CS. To summarize, the retrograde conduction in first beat was all via AV node. The second beat had a true fused atrial activation via AP and AV node (Appendix 1- Table 1). The robust AV node was responsible for this fused conduction. Post ablation PHP revealed a pure nodal response (Appendix 2). It also revealed a very brisk AV nodal conduction as noted by the short VA time supporting our conjecture. The response to VES became clearly concentric and decremental. A nodal response in the presence of AP is usually seen when the AP is slowly conducting or decremental or away from septum.1 When mixed conduction happens during a PHP, there can be 4 possible patterns as described by Hirao et al (AVN/AP; AVN/Fusion; Fusion/AP and Fusion/Fusion). Our case corroborated with Pattern 5 described in the seminal paper (AVN / Fusion pattern).1 In their cohort, this finding was observed in 14% (8 out of 56) of the postero-septal AP cases. In contrast, the incidence of fusion response in midseptal and anteroseptal APs in their cohort was low and AP/AP pattern was noted in the majority. Our case highlights that a mixed or fused VA conduction can be noted in the presence of non-decremental AP if the nodal conduction is fast. Careful analysis of atrial activation sequence is important to avoid confounding interpretation. The authors declare no conflicts of interest. The data that support the findings of this study are available from the corresponding author upon reasonable request. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
No takes yet. Share an insight, caveat, or question.
Bera et al. (2023) conducted a case report in Supraventricular tachycardia (n=1). Para-Hisian Pacing maneuver was evaluated on Mechanism of contradictory response during PHP maneuver. In a 24-year-old man with supraventricular tachycardia, para-Hisian pacing revealed a mixed or fused ventriculo-atrial conduction via both an accessory pathway and a fast-conducting AV node.
Synapse has enriched 10 related papers. Consider them for comparative context: