Key result
A high integrated risk score (2-5) was associated with a significantly greater seven-year incidence of persistent atrial fibrillation compared to a low score (0-1) (22.8% vs. 5.3%).
Why the study?
What are the predictors of persistent atrial fibrillation in patients after dual-chamber pacemaker implantation?
Cohort (n=649)
No
What are the predictors of persistent atrial fibrillation in patients after dual-chamber pacemaker implantation?
Answers are grounded in this paper and cite their sources.
The integrated risk score may support post-pacemaker AF risk stratification; observational data leaves open prospective validation before practice change.
Persistent atrial fibrillation (PeAF) predictors after dual-chamber pacemaker (PM) implantation remain unclear. We sought to determine these predictors and establish an integrated scoring model. Data were retrospectively reviewed for 649 patients (63.8 ± 12.3 years, 48.6% male, mean CHA2DS2-VASC score 2.7 ± 2.0) undergoing dual-chamber PM implantation. PeAF was defined as documented AF on two consecutive electrocardiograms acquired ≥7 days apart. During a 7.1-year median follow-up (interquartile range 4.5-10.1 years), 67 (10.3%) patients had PeAF. Multivariable analysis showed the following independent predictors of future PeAF: ischemic stroke or transient ischemic accident history (hazard ratio [HR] 2.03, 95% confidence interval [CI] 1.03-3.50, p = 0.040), atrial fibrillation/flutter history (HR 1.80, 95% CI 1.01-3.20, p = 0.046), sinus node disease (HR 2.24, 95% CI 1.16-4.35, p = 0.016), left atrial enlargement (>45 mm, HR 2.14, 95% CI 1.26-3.63, p = 0.005), and time in automatic mode switching >1% at first follow-up interrogation (HR 2.58, 95% CI 1.51-4.42, p < 0.001). An integrated scoring model combining these predictors showed good discrimination performance at the seven-year follow-up. (C-statistic 0.716, 95% CI 0.629-0.802, p < 0.001). Significantly greater seven-year PeAF incidences were seen in patients with higher scores (2-5) than in those with lower scores (0-1) (22.8% ± 3.8% vs. 5.3% ± 1.7%, p < 0.001). In conclusion, an integrated scoring model combining clinical, echocardiographic, and electrocardiographic characteristics is useful for predicting future PeAF in patients with a dual-chamber PM.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2016) conducted a cohort in Dual-chamber pacemaker implantation (n=649). High integrated risk score (2-5) vs. Low integrated risk score (0-1) was evaluated on Seven-year incidence of persistent atrial fibrillation (p=<0.001). A high integrated risk score (2-5) was associated with a significantly greater seven-year incidence of persistent atrial fibrillation compared to a low score (0-1) (22.8% vs. 5.3%).