With the popularity of micro-processors, digital controllers are widely used in uninterruptible power supply (UPS) inverters. These digital control systems of UPS inverters require a time interval for sampling and computation, which sometimes affects the performance of inverters. In this paper, the problem of time delay in digital control of a UPS inverter is discussed. Then two novel pulsewidth modulation (PWM) methods, the two-polarity PWM method and the asymmetric PWM method, are proposed to handle the time-delay problem. Both of these PWM methods can achieve a wide range of duty ratio between 0.05-0.95, which is independent of inverter model. Furthermore, they are easy to implement using a digital micro-controller. Experimental results are presented in the paper to verify feasibility of the proposed PWM methods.
No takes yet. Share an insight, caveat, or question.
Deng et al. (2005) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: