Key result
Short (1 min) cryoballoon applications resulted in similar 1-year freedom from atrial fibrillation compared to medium (2 min) and long (3 min) applications.
Why the study?
To evaluate the minimal cryoballoon application duration necessary to achieve pulmonary vein isolation in patients with paroxysmal AF with the aim of reducing complications.
Does shortening cryoballoon application time to <2 minutes reduce phrenic nerve injury without compromising 1-year freedom from AF in patients with paroxysmal AF?
RCT (n=222)
randomized
Does shortening cryoballoon application time to <2 minutes reduce phrenic nerve injury without compromising 1-year freedom from AF in patients with paroxysmal AF?
Shortening cryoballoon applications to <2 minutes for the right superior pulmonary vein reduces phrenic nerve injury without compromising 1-year freedom from AF.
Answers are grounded in this paper and cite their sources.
Supports 1-min cryoballoon applications to reduce phrenic nerve injury; confirms comparable 1-year AF freedom versus longer durations in this paroxysmal AF RCT.
BACKGROUND: In the 123-study, we prospectively assessed, in a randomized fashion, the minimal cryoballoon application time necessary to achieve pulmonary vein (PV) isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) with the aim to reduce complications by shortening the application duration. The first results of this study demonstrated that shortened cryoballoon applications (<2 minutes) resulted in less phrenic nerve injury (PNI) without compromising acute isolation efficacy for the right PVs. We now report the 1-year follow-up results regarding safety and efficacy of shorter cryoballoon applications. METHODS: A total of 222 patients with AF were randomized to two applications of 1 min "short," 2 min "medium," or 3 min "long" duration, 74 per group. Recurrence of AF and PV reconduction at 1-year follow-up were assessed. RESULTS: The overall 1-year freedom from AF was 79% and did not differ significantly between the short, medium, and long application groups (77%, 74%, and 85% for short, medium, and long application groups, respectively; P = 0.07). In 30 patients, a redo PVI procedure was performed. For all four PVs, there was no significant difference in reconduction between the three groups. Reconduction was most common in the left superior PV (57%). The right superior PV (RSPV) showed significantly less reconduction (17%) compared to the other PVs. CONCLUSIONS: Shortening cryoballoon applications of the RSPV to <2 minutes results in less PNI, while acute success and 1-year freedom from AF are not compromised. Therefore, shorter cryoballoon applications (especially) in the RSPV could be used to reduce PNI.
No takes yet. Share an insight, caveat, or question.
Molenaar et al. (2020) conducted an RCT in paroxysmal atrial fibrillation (AF) (n=222). Short (1 min) cryoballoon applications vs. Medium (2 min) or long (3 min) cryoballoon applications was evaluated on 1-year freedom from AF (p=0.07). Short (1 min) cryoballoon applications resulted in similar 1-year freedom from atrial fibrillation compared to medium (2 min) and long (3 min) applications.
Synapse has enriched 10 related papers. Consider them for comparative context: