Keeping the sampling rate as low as possible in wearable biomedical sensors can significantly reduce computational complexity and energy consumption.
Answers are grounded in this paper and cite their sources.
Lower sampling rates may reduce energy use in wearables; leaves open validation across clinical algorithms and devices.
Long battery runtime is one of the most wanted properties of wearable sensor systems. The sampling rate has an high impact on the power consumption. However, defining a sufficient sampling rate, especially for cutting edge mobile sensors is difficult. Often, a high sampling rate, up to four times higher than necessary, is chosen as a precaution. Especially for biomedical sensor applications many contradictory recommendations exist, how to select the appropriate sample rate. They all are motivated from one point of view — the signal quality. In this paper we motivate to keep the sampling rate as low as possible. Therefore we reviewed common algorithms for biomedical signal processing. For each algorithm the number of operations depending on the data rate has been estimated. The Bachmann-Landau notation has been used to evaluate the computational complexity in dependency of the sampling rate. We found linear, logarithmic, quadratic and cubic dependencies.