Key result
Implementation of an electronic order set based on AHA practice standards increased appropriate electrocardiographic monitoring with no increase in adverse events.
Why the study?
Many hospitalized patients receive unnecessary electrocardiographic monitoring, contributing to patient inconvenience, clinician alarm fatigue, and delayed admissions.
Does the introduction of an electronic order set based on AHA practice standards improve appropriate electrocardiographic monitoring in hospitalized adult patients?
Does the introduction of an electronic order set based on AHA practice standards improve appropriate electrocardiographic monitoring in hospitalized adult patients?
Implementing an electronic order set based on AHA guidelines significantly improves the appropriateness of inpatient electrocardiographic monitoring without increasing adverse events.
Answers are grounded in this paper and cite their sources.
May support electronic order sets to improve ECG monitoring appropriateness; hypothesis-generating and requires randomized confirmation before practice change.
BACKGROUND: Although electrocardiographic monitoring is common in hospitalized patients, many patients receive unnecessary monitoring, contributing to patients' inconvenience, clinicians' alarm fatigue, and delayed admissions. OBJECTIVE: To evaluate the impact of implementation of an electronic order set based on the American Heart Association practice standards for electrocardiographic monitoring on the occurrence of appropriate monitoring. METHODS: The sample for this preintervention-to-postintervention quasi-experimental study consisted of 297 adult patients on medical, surgical, neurological, oncological, and orthopedic patient care units that used remote electrocardiographic monitoring in a 627-bed hospital in Minneapolis, Minnesota. The intervention was the introduction into the electronic health record of order sets prompting physicians to order electrocardiographic monitoring per the American Heart Association practice standards. Indications for monitoring according to the practice standards and adverse outcomes (unexpected transfer to intensive care unit, death, code blue events, and call for the rapid response team) were compared before and after implementation of the order set. No significant increase in adverse patient outcomes was noted. CONCLUSIONS: Implementation of the practice standards via an electronic order set was associated with a statistically significant increase in appropriate monitoring, with no increase in adverse events. Use of electronic order sets is an effective and safe way to enhance appropriate electrocardiographic monitoring.
No takes yet. Share an insight, caveat, or question.
Sendelbach et al. (2019) studied Hospitalized patients requiring electrocardiographic monitoring (n=297). Electronic order set based on AHA practice standards vs. Preintervention usual care was evaluated on Occurrence of appropriate monitoring and adverse outcomes (p=.001). Implementation of an electronic order set based on AHA practice standards increased appropriate electrocardiographic monitoring with no increase in adverse events.
Synapse has enriched 10 related papers. Consider them for comparative context: