Key result
A directed network mapping approach successfully located a stable rotor in a simulated 3D model of human atrial fibrillation by detecting a repeating cycle between 3 nodes.
Why the study?
Catheter ablation outcomes for AF remain suboptimal partly because ablation focuses on anatomic rather than patient-specific functional targets, which remain challenging to identify.
Directed network mapping of unipolar electrograms can successfully localize stable rotors in a computational 3D model of atrial fibrillation, offering a potential future tool for guiding ablation.
Hypothesis-generating in computational AF models; leaves open translation of directed network mapping to clinical rotor ablation.
Catheter ablation for atrial fibrillation (AF) is one of the most commonly performed electrophysiology procedures. Despite significant advances in our understanding of AF mechanisms in the last years, ablation outcomes remain suboptimal for many patients, particularly those with persistent or long-standing AF. A possible reason is that ablation techniques mainly focus on anatomic, rather than patient-specific functional targets for ablation. The identification of such ablation targets remains challenging. The purpose of this study is to investigate a novel approach based on directed networks, which allow the automatic detection of important arrhythmia mechanisms, that can be convenient for guiding the ablation strategy. The networks are generated by processing unipolar electrograms (EGMs) collected by the catheters positioned at the different regions of the atria. Network vertices represent the locations of the recordings and edges are determined using cross-covariance time-delay estimation method. The algorithm identifies rotational activity, spreading from vertex to vertex creating a cycle. This work is a simulation study and it uses a highly detailed computational 3D model of human atria in which sustained rotor activation of the atria was achieved. Virtual electrodes were placed on the endocardial surface, and EGMs were calculated at each of these electrodes. The propagation of the electric wave fronts in the atrial myocardium during AF is very complex, so in order to properly capture wave propagation patterns, we split EGMs into multiple short time frames. Then, a specific network for each of these time frames was generated, and the cycles repeating in consecutive networks point us to the stable rotor's location. The respective atrial voltage map served as reference. By detecting a cycle between the same 3 nodes in 19 out of 58 networks, where 10 of these networks were in consecutive time frames, a stable rotor was successfully located.
No takes yet. Share an insight, caveat, or question.
Vila et al. (2021) studied Atrial Fibrillation. Directed network mapping vs. Reference atrial voltage map was evaluated on Stable rotor localization. A directed network mapping approach successfully located a stable rotor in a simulated 3D model of human atrial fibrillation by detecting a repeating cycle between 3 nodes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: