Key result
Hemodynamic monitoring and tourniquets yield zero iatrogenic fractures in pediatric osteogenesis imperfecta procedures.
Why the study?
Healthcare providers have traditionally avoided NIBP cuffs and extremity tourniquets in osteogenesis imperfecta to prevent iatrogenic fractures, but whether these procedures actually cause complications was unproven.
Does the intraoperative use of NIBP cuffs, arterial lines, and extremity tourniquets cause iatrogenic fractures in pediatric patients with osteogenesis imperfecta?
Cohort (n=49)
No
Does the intraoperative use of NIBP cuffs, arterial lines, and extremity tourniquets cause iatrogenic fractures in pediatric patients with osteogenesis imperfecta?
Intraoperative hemodynamic monitoring with NIBP cuffs and extremity tourniquets appears to be safe and may be selectively used in pediatric patients with osteogenesis imperfecta.
Answers are grounded in this paper and cite their sources.
Supports selective NIBP/tourniquet use in pediatric OI surgery; leaves open need for prospective confirmation.
Osteogenesis imperfecta (OI) is a rare genetic connective-tissue disorder with bone fragility. To avoid iatrogenic fractures, healthcare providers have traditionally avoided using non-invasive blood pressure (NIBP) cuffs and extremity tourniquets in the OI population in the perioperative setting. Here, we hypothesize that these procedures do not lead to iatrogenic fractures or other complications in patients with OI. A retrospective study of all children with OI who underwent surgery at a single tertiary care children's hospital from 1998 to 2018 was performed. Patient positioning and the use of NIBP cuffs, arterial lines, and extremity tourniquets were documented. Fractures and other complications were recorded. Forty-nine patients with a median age of 7.9 years (range: 0.2-17.7) were identified. These patients underwent 273 procedures, of which 229 were orthopaedic operations. A total of 246 (90.1%) procedures included the use of an NIBP cuff, 61 (22.3%) an extremity tourniquet, and 40 (14.7%) an arterial line. Pediatric patients with OI did not experience any iatrogenic fractures related to hemodynamic monitoring or extremity tourniquet use during the 20-year period of this study. Given the benefits of continuous intra-operative hemodynamic monitoring and extremity tourniquets, we recommend that NIBP cuffs, arterial lines, and tourniquets be selectively considered for use in children with OI.
No takes yet. Share an insight, caveat, or question.
Ross et al. (2020) conducted a cohort in Osteogenesis imperfecta (n=49). Non-invasive blood pressure (NIBP) cuffs, arterial lines, and extremity tourniquets was evaluated on Iatrogenic fractures related to NIBP use, extremity tourniquet use, or patient positioning. Pediatric patients with osteogenesis imperfecta experienced zero iatrogenic fractures related to hemodynamic monitoring or extremity tourniquet use across 273 procedures.