Key result
Modified Nicks aortic root enlargement yields ~93% long-term survival with zero patch aneurysms.
Why the study?
To determine the influence of specific surgical techniques on avoiding complications and to evaluate the long-term stability of aortic root enlargement during aortic valve replacement.
Does Nicks' posterior aortic root enlargement with a retained pericardial collar and Teflon-buttressed sutures prevent prosthesis-patient mismatch and late aneurysm formation in patients with a small aortic annulus?
Observational (n=115)
No
Does Nicks' posterior aortic root enlargement with a retained pericardial collar and Teflon-buttressed sutures prevent prosthesis-patient mismatch and late aneurysm formation in patients with a small aortic annulus?
Aortic root enlargement via Nicks' procedure using an autologous pericardial collar is a durable surgical adjunct that effectively prevents prosthesis-patient mismatch without the long-term risk of pseudoaneurysm formation or structural failure.
Answers are grounded in this paper and cite their sources.
Adds long-term evidence for pericardial Nicks' enlargement in small annuli; leaves open broader adoption pending prospective validation.
OBJECTIVES: To determine the influence of surgical techniques adopted to avoid suture line disruption, periprosthetic leakage, patch dislodgement, pericardial patch aneurysm formation, and the long-term stability of aortic root enlargement (ARE) during aortic valve replacement (AVR). METHODS: One hundred fifteen patients undergoing AVR or combined aortic and mitral valve replacements with Nicks' posterior ARE between 1997 and 2019 underwent long-term echocardiographic and angio-computed tomographic evaluation. Age was 11-72 years (AVR: median, 30; interquartile range, 21-47 years; AVR and mitral valve replacement: median, 27.5; interquartile range, 20-37.5 years). The aortotomy was closed using autologous pericardial patch and Teflon-buttressed sutures. RESULTS: Hospital mortality was 1.7% (n = 2), with 4 (3.5%) late deaths. At a mean follow-up of 123.11 ± 77.67 months, the survival probability from Kaplan-Meier was 93.25 ± 0.03%. No cases of severe prosthesis-patient mismatch (PPM) were observed, and only 2 patients had moderate PPM. Median aortic root diameters at the level of sinus of Valsalva and sinotubular junction were 32 (29-35) mm and 33 (30-36) mm, respectively, at discharge, and were 33 (30-36) mm, and 33 (31-37) mm, respectively, at latest follow-up, with no cases of late pericardial patch aneurysm. CONCLUSIONS: ARE is a safe adjunct to AVR in patients with a small aortic annulus to prevent PPM. Retention of a pericardial collar and Teflon-buttressed sutures is an expedient, safe, and effective technique in reducing bleeding at the enlarged ventriculo-aortic junction. Autologous pericardial patch aortoplasty is not associated with late aneurysm/pseudoaneurysm formation.
No takes yet. Share an insight, caveat, or question.
Chowdhury et al. (2020) conducted an observational in Aortic valve disease with small aortic annulus requiring aortic root enlargement (n=115). Nicks' posterior aortic root enlargement using autologous pericardial patch and Teflon-buttressed sutures was evaluated on Survival probability from Kaplan-Meier at 276 months (95% CI 0.85-0.96). Nicks' posterior aortic root enlargement using an autologous pericardial collar and Teflon-buttressed sutures achieved 93.3% survival at 276 months with zero cases of late pericardial patch aneurysm.
Synapse has enriched 10 related papers. Consider them for comparative context: