Why the study?
Does the ST/HR slope or exercise thallium imaging improve diagnostic accuracy for coronary artery disease compared to conventional S-T segment criteria?
Does the ST/HR slope or exercise thallium imaging improve diagnostic accuracy for coronary artery disease compared to conventional S-T segment criteria?
Exercise thallium SPECT is significantly more accurate than both the ST/HR slope and conventional S-T segment criteria for diagnosing coronary artery disease, whereas the ST/HR slope offers no significant overall advantage over conventional criteria.
Answers are grounded in this paper and cite their sources.
Thallium SPECT may be preferred for CAD diagnosis; leaves open whether ST/HR slope adds value beyond conventional criteria.
The S-T segment/heart rate (ST/HR) slope has been proposed as a more accurate electrocardiographic criterion for the diagnosis of coronary artery disease, but studies comparing the diagnostic value of the ST/HR slope with exercise thallium imaging are scant. The aims of this study were to assess the diagnostic accuracy of the ST/HR slope, conventional S-T segment criteria and exercise thallium imaging in detecting coronary artery disease and to evaluate the effect of exercise level on the sensitivity and specificity of these three techniques. Ninety consecutive patients underwent treadmill testing and exercise thallium single-photon emission computed tomography (SPECT) simultaneously. All 90 patients also underwent coronary angiography within 1 month of the exercise test. We found that exercise thallium SPECT had a significantly higher diagnostic accuracy than either the ST/HT slope or conventional S-T segment criteria (thallium imaging 82%, ST/HR slope 67%, conventional S-T segment criteria 63%). The overall accuracy of the ST/HR slope was slightly but insignificantly greater than conventional S-T segment criteria (ST/HR slope 67%, conventional S-T segment criteria 63%; p = 0.639). In 50 patients with a lower exercise level, defined as not achieving 85% of their maximal predicted heart rate, the accuracy of the ST/HR slope was insignificantly greater (ST/HR slope 72%, conventional S-T segment criteria 66%; p = 0.517). In 40 patients with adequate exercise, the accuracy rate was the same (60%) for both the ST/HR slope and conventional S-T segment criteria. We conclude that exercise thallium imaging is more accurate than the ST/HR slope in diagnosing coronary artery disease and that the accuracy of the ST/HR slope is marginally better than conventional S-T segment criteria only in patients with a lower exercise level, and not in those with adequate exercise.
No takes yet. Share an insight, caveat, or question.
Liu et al. (1998) studied this question.