Key result
High visit-to-visit heart rate variability (Q4) was an independent predictor of all-cause death (HR 1.45; 95% CI 1.07-1.98), ischemic stroke/systemic embolism, and heart failure.
Why the study?
Visit-to-visit heart rate variability has been linked to adverse cardiovascular outcomes, but its predictive value in patients with nonvalvular AF required investigation.
Does high visit-to-visit heart rate variability predict all-cause death, ischemic stroke/systemic embolism, and heart failure in patients with nonvalvular atrial fibrillation?
Cohort (n=3,174)
Yes
Does high visit-to-visit heart rate variability predict all-cause death, ischemic stroke/systemic embolism, and heart failure in patients with nonvalvular atrial fibrillation?
Answers are grounded in this paper and cite their sources.
High visit-to-visit heart rate variability is an independent predictor of adverse clinical outcomes including death, stroke, and heart failure in patients with nonvalvular atrial fibrillation.
BACKGROUND: Visit-to-visit heart rate variability (VVV-HR) has been associated with adverse cardiovascular outcomes. We aimed to determine the predictive value of VVV-HR for adverse clinical outcomes in patients with nonvalvular atrial fibrillation (AF). METHODS: We used data from a prospective multicenter AF registry of 27 hospitals in Thailand during 2014 to 2017. After the baseline visit, patients were followed up every 6 months until 3 years. VVV-HR was calculated from the standard deviation of heart rate data from baseline visit and every follow-up visit. VVV-HR was categorized into four groups according to the quartiles. Clinical outcomes were all-cause death, ischemic stroke/systemic embolism (SE), and heart failure. Cox proportional hazard models were used for multivariable analysis. RESULTS: There were a total of 3,174 patients (mean age: 67.7 years; 41.8% female). The incidence rates of all-cause death, ischemic stroke/SE, and heart failure were 3.10 (2.74-3.49), 1.42 (1.18-1.69), and 2.09 (1.80-2.42) per 100 person-years respectively. The average heart rate was 77.8 ± 11.0 bpm and the average of standard deviation of heart rate was 11.0 ± 5.9 bpm. VVV-HR Q4 was an independent predictor of all-cause death, ischemic stroke/SE, and heart failure with adjusted hazard ratios of 1.45 (95% confidence interval: 1.07-1.98), 2.02 (1.24-3.29), and 2.63 (1.75-3.96), respectively. VVV-HR still remained a significant predictor of clinical outcomes when analyzed based on coefficient of variation and variability independent of mean. CONCLUSION: -curve appearance was demonstrated for the effect of VVV-HR on all-cause death.
No takes yet. Share an insight, caveat, or question.
Krittayaphong et al. (2023) conducted a cohort in nonvalvular atrial fibrillation (AF) (n=3,174). Visit-to-visit heart rate variability (VVV-HR) highest quartile (Q4) vs. Lower quartiles of VVV-HR was evaluated on All-cause death (HR 1.45, 95% CI 1.07-1.98). High visit-to-visit heart rate variability (Q4) was an independent predictor of all-cause death (HR 1.45; 95% CI 1.07-1.98), ischemic stroke/systemic embolism, and heart failure.
Synapse has enriched 10 related papers. Consider them for comparative context: