Answers are grounded in this paper and cite their sources.
Response addresses methodological aspects and future research directions regarding gaze position error in subacute dizziness.
Dear Editor, We appreciate the thoughtful comments provided in the letter regarding our recent article “Symptom and Handicap Severity in Subacute Dizzy Patients: The Role of Gaze Position Error in Video Head Impulses.” We welcome the opportunity to clarify several methodological aspects and to address the points raised. Our response below aims to place our findings in the appropriate context, to explain the rationale behind our study design, and to outline how future research may further expand on the questions raised. Quantification of GPE and algorithm Our system’s eye tracker has a sampling frequency of 250 Hz, corresponding to a temporal resolution of 4 ms. Thus, the detection window for identifying head velocity zero-crossings is inherently limited by this resolution. We would like to clarify that the authors of the letter cite in their comment Schubert et al1; however, this paper did not investigate the effect of detection-window delays on gaze position error (GPE). Specifically, they did not examine whether a 5 ms delay in zero-crossing detection increases GPE measurement error. Instead, their study focused on identifying oculomotor strategies—such as compensatory and corrective saccades—used by patients with unilateral and bilateral vestibular hypofunction during passive and active head impulses, and on quantifying how these strategies influenced GPE. Their main finding was that compensatory saccades significantly reduced GPE, not that detection-window errors biased the measurement. The detection window bias introduced in our data is negligible for several reasons. First, the growth of GPE over time in patients with deficient VOR occurs predominantly at higher head velocities, rather than at the time of the head reaching zero velocity or the first zero crossing. Second, due to the common overshoot of head movements at the end of head impulse and the interpolation algorithms implemented in the vHIT goggles, any small temporal misalignment has minimal effect on gain calculation at the critical point of head stopping. We deliberately included all traces that were accepted by the built-in vHIT goggle algorithm. The built-in vHIT algorithm accepts head impulses only when specific criteria are met. Valid impulses must reach a peak head velocity between 160/s and 310 degrees/s. The onset of the impulse is defined at 20 degrees/s, and the time to peak velocity must be ≤100 ms. Impulses outside these limits are automatically discarded to ensure reliable and standardized measurements. No additional manual trial exclusion was performed. This design choice was motivated by our aim to replicate real-world clinical conditions where clinicians rely on the device’s automated acceptance criteria rather than post hoc data cleaning. This approach avoids subjective bias and reflects the reproducibility of vHIT testing in clinical practice. To further ensure robust measurements, we averaged all calculated GPEs from each vHIT impulses trial per side. As shown by Zamaro et al.2 such averaging significantly reduces variability in gain estimation, even in the presence of minor artifacts. Thus, the methodological rigor of our dataset is maintained without the need for additional exclusion thresholds. Analysis of DHI subscales and potential interaction effects We agree with the authors of the letter that interaction effects between demographic factors (eg, sex and age) and vestibular parameters (eg, GPE and VOR gain) may provide valuable insight into the mechanisms underlying dizziness-related handicap. The authors of the letter cite several studies, including Formeister et al.3, which, however, do not provide evidence in support of the points and criticisms they raise. Formeister et al.3 examined adult patients in a dizziness clinic, including individuals with chronic vestibular syndromes. Importantly, their cohort did not consist exclusively of patients in the acute phase after a vestibular syndrome, as was the case in our study, and the etiology of dizziness or imbalance was not considered as an inclusion criterion when enrolling patients. Moreover, the cited work relied solely on questionnaire-based measures (sociodemographic information, depression, anxiety, and dizziness), without correlation to objective vestibular test results such as vHIT-derived VOR gain or GPE. In our study, subgroup analyses stratified by both demographic variables and vestibular function (eg, female vs. male with normal vs. abnormal VOR gain) were not feasible due to the limited sample size. Such stratification would have substantially reduced statistical power and increased the risk of Type II error, that is, failing to detect existing interaction effects. For this reason, we restricted our analysis to main effects and marginal correlations, acknowledging this as an important limitation. Regarding longitudinal validation We would like to emphasize that the scope of our study was explicitly defined in the title and design: we examined gaze position error (GPE) in patients with subacute dizziness, not in those with chronic vestibular syndromes characterized by symptoms persisting for months. Accordingly, our protocol included a single follow-up assessment at 30 days, which was chosen to capture early patterns of compensation and residual symptoms. In addition, we mention in the limitations section that our study focused on the subacute stage of AUVP, limiting its applicability to patients with chronic vestibular symptoms, and we suggest further research to investigate whether GPE remains a relevant marker of persistent dizziness beyond the 1-month follow-up period. We fully agree that longer observational periods could provide valuable insights into the durability of vestibular compensation, the role of multisensory integration, and the potential development of persistent postural-perceptual dizziness (PPPD). Future studies with extended follow-up intervals (eg, 3 mo or longer) will be needed to address these important questions in more detail. Conflict of Interest The authors disclose no conflicts of interest. Funding This study was supported by the Swiss National Science Foundation, #320030_173081. Acknowledgments Eyeseetec company loaned the VOG goggles. Availability of data and material The data that support the findings of this study are available from the corresponding author [G.M.], upon reasonable request.
No takes yet. Share an insight, caveat, or question.
Korda et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: