Key result
Wedge-shaped third-rib detachment in Mini-AVR achieves mean aortic cross-clamp times of ~79 minutes.
Why the study?
The restricted surgical field in Mini-AVR via right anterior thoracotomy makes the procedure challenging and limits its application, prompting a wedge-shaped third-rib detachment technique to expand surgical exposure.
Does wedge-shaped detachment of the third rib facilitate surgical exposure and performance in patients undergoing Mini-AVR via right anterior thoracotomy?
Observational (n=176)
No
Does wedge-shaped detachment of the third rib facilitate surgical exposure and performance in patients undergoing Mini-AVR via right anterior thoracotomy?
Wedge-shaped detachment of the third rib during Mini-AVR is a feasible technique that facilitates surgical exposure, particularly in patients with less favorable anatomy.
Background/Objectives: Minimally invasive aortic valve replacement via right anterior thoracotomy (Mini-AVR) has been proven safe and effective. However, the restricted surgical field through this approach makes this surgery challenging and therefore limits its application. A simple modification of an exposure technique involving third-rib detachment from the sternum in a wedge shape allows for expansion of the surgical field to the left, facilitating surgical exposure and performance, which may shorten the learning curve for surgeons, and make this surgery applicable to patients with less favorable anatomy. Methods: This is a retrospective study. From 2019 to 2024, 176 patients aged 62.9 ± 17.5 years old underwent Mini-AVR via right anterior thoracotomy with third-rib detachment at our hospital in Vietnam. Results: A mechanical prosthesis was used in 98 patients (55.7%) and bioprosthesis in 78 patients (44.3%). Leftward and deep aorta position were seen in 57 (32.4%) and 18 (10.2%) patients, respectively. The aortic cross-clamp and bypass time were 78.69 ± 24.1 and 128.1 ± 26.3 min, respectively. Root enlargement was performed in 2 patients (1.1%). Conclusions: Wedge-shape detachment of the third rib from the sternum in Mini-AVR allows for expansion of the surgical field to the left, facilitating surgical exposure and performance, especially in patients with less favorable anatomy.
No takes yet. Share an insight, caveat, or question.
Nguyen et al. (2026) conducted an observational in Aortic valve disease requiring replacement (n=176). Wedge-shaped third-rib detachment in Mini-AVR was evaluated.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: