Answers are grounded in this paper and cite their sources.
Prospective trial compares DCE-CT and PET-CT accuracy in characterizing lung lesions, suggesting enhanced diagnostic potential.
Background The positron emission tomography–computed tomography (PET-CT) is the cornerstone in oncologic imaging because of its high sensitivity. However, its specificity is largely compromised by the false-positive uptake in benign infectious and inflammatory conditions. The dynamic contrast-enhanced computed tomography (DCE-CT) is a promising imaging technique that can eventually provide insight into the tumor vascularity and angiogenesis through quantification of tumor perfusion parameters like peak enhancement, net enhancement (wash-in), absolute loss of enhancement (wash-out), as well as the time–intensity curve morphology. Aim of the work : To compare the efficacy and accuracy of DCE-CT versus PET-CT in the characterization of suspicious lung lesions using clinico-laboratory correlation, pathological verification, and follow-up, as well as receiver-operating characteristics (ROC) statistical analysis. Results Forty patients with indeterminate pulmonary lesions were prospectively enrolled in this study during the period between September/2023 and January/2026. All patients underwent both DCE-CT and PET-CT examinations. Automatic calculations of relevant cutoff values were encountered; then, the ROC analyses and the tests of accuracy were applied. The study was conducted by four expert radiologists, single oncologist, and a single pulmonologist. Peak enhancement : At the initially used “40 HU” value, positive statistical significance was encountered ( p value = 0.003). The area under the ROC curve (AUC) was 0.74, 95% CI [0.57, 0.92], SE = 0.09, p = 0.006. At the estimated “50 HU” threshold, the performance was statistically better. Net enhancement/wash-in : At the initially used “25 HU” value, positive statistical significance was encountered ( p value = < 0.0001). The area under the ROC curve (AUC) was 0.83, 95% CI [0.68, 0.99], SE = 0.08, p < 0.001. At the estimated “23 HU” threshold, the performance was statistically better. Final curve : Type I curve was established in 95% of malignant lesions. On the other hand, type II and III curves were established in 78% and 11% of non-malignant lesions. Positive statistical significance was encountered ( p value = < 0.0001). The overall accuracy of the DCE-CT curve was higher than that of PET-CT SUV (92.5% compared to 80%), with much higher specificity; however, the sensitivity of the DCE-CT is lower. Conclusions The DCE-CT constitutes a reliable, cost-effective, and widely available alternative for the characterization of the suspicious pulmonary lesions. Quantitative perfusion parameters, particularly wash-in, wash-out, and curve-type analysis, can serve as valuable indicators of malignancy and improve diagnostic confidence in indeterminate cases. Integrating both modalities may yield a more holistic diagnostic model to enhance precision in lung cancer detection and management.
No takes yet. Share an insight, caveat, or question.
Alsamahi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: