Dynamic analysis evaluates resonance risk in large vertical pumping stations, indicating design improvements for safety.
Pumping stations serve as the foundation platform for large-scale vertical fluid machinery, and their structural dynamics directly govern the vibration levels and long-term reliability of the installed pump units. In low-head vertical pumping stations, the interaction among the massive underwater substructure, flexible above-ground powerhouse, and surrounding backfill soil creates a complex dynamic system whose behavior remains insufficiently characterized. This study presents a comprehensive dynamic analysis of a large-scale vertical pumping station using a high-fidelity three-dimensional finite element model that incorporates the powerhouse superstructure, submerged concrete substructure, and backfill soil. Modal analysis under four boundary condition scenarios—varying in soil participation and interface contact conditions—systematically quantifies the influence of soil–structure interaction on natural frequencies and mode shapes. Resonance verification against three primary excitation sources—rotational frequency (4.917 Hz), blade passage frequency (24.583 Hz), and rotor–stator interaction frequency (196.667 Hz)—is extended from the first 50 modes to the 400th mode to assess potential high-order resonance risks. Results show that the roof slab, with its large span and low stiffness, exhibits the highest vibration susceptibility. For the rotational frequency, modes 4–12 fall below the 20% code-specified safety margin but rapidly exceed the threshold thereafter. For the blade passage frequency, the separation ratio decreases progressively with increasing mode order within the first 50 modes, and the extended analysis up to the 400th mode shows that the separation ratio remains well above 20% throughout modes 51–400. Consequently, no substantial resonance risk exists for the blade passage frequency within the entire computed range. The rotor–stator interaction frequency remains safely separated with margins exceeding 95%. These findings demonstrate the profound influence of soil–structure interaction and confirm that, despite a decreasing trend in frequency separation at higher orders, the blade passage frequency poses no substantial resonance risk up to the 400th mode. This work provides a rigorous analytical framework for vibration-informed design and optimization of pump foundation systems, with direct implications for the reliability and operational safety of large-scale vertical fluid machinery.
No takes yet. Share an insight, caveat, or question.
匡可心 et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: