Key result
Decreased HRV links to Parkinson's disease diagnosis, with low-frequency power correlating with tremor severity.
Why the study?
Reduced HRV is associated with Parkinson's disease, but studies examining the implications of HRV measures for the clinical manifestations of PD have shown inconclusive results.
Does long-term HRV monitoring using a wearable ECG device differentiate patients with Parkinson's disease from healthy controls and correlate with clinical features?
Case-Control (n=37)
No
Does long-term HRV monitoring using a wearable ECG device differentiate patients with Parkinson's disease from healthy controls and correlate with clinical features?
Long-term HRV monitoring via a wearable ECG device identifies reduced low-frequency power in Parkinson's disease, which correlates with tremor severity and cerebellar volume.
Answers are grounded in this paper and cite their sources.
May support wearable HRV monitoring in Parkinson's disease; leaves open diagnostic utility pending prospective validation.
Introduction Heart rate variability (HRV) reflects cardiac autonomic regulation, and reduced HRV is associated with Parkinson’s disease (PD). However, studies regarding the implications of HRV measures for the clinical manifestations of PD have shown inconclusive results. We examined the relationship between HRV measures obtained via long-term monitoring using a wearable electrocardiogram (ECG) device and the diagnosis and clinical characteristics of PD. Methods Seventeen controls and 20 patients with PD were prospectively enrolled. The HRV measures were recorded using a wearable ECG device for up to 72 h. Time- and frequency-domain measures were derived from the HRV analysis, and their association with PD diagnosis and clinical features was investigated. We investigated their association with neuroimaging biomarkers using magnetic resonance imaging to explore the underlying neural correlates. Results The diagnosis of PD was associated with several HRV measures, including a decreased standard deviation of N-N intervals, standard deviation of all heart rates, and low-frequency (LF) power. Among these HRV measures, only LF power was associated with clinical features of PD. LF power was positively correlated with the tremor sub-score ( r = 0.500; p = 0.035) and negatively associated with the left ( r = −0.598; p = 0.024) and right ( r = −0.693; p = 0.006) cerebellar hemispheres in patients with PD. Conclusion Low-frequency power may be used as a biomarker for tremor-associated pathophysiology of PD. Moreover, a wearable ECG device with its capability for long-term monitoring might be a promising tool for diagnosing PD.
No takes yet. Share an insight, caveat, or question.
Park et al. (2025) conducted a case-control in Parkinson's disease (n=37). Heart rate variability (HRV) measures vs. Healthy controls was evaluated on Parkinson's disease diagnosis (SDNN) (OR 0.725, 95% CI 0.578-0.909, p=0.005). Decreased low-frequency power and other heart rate variability measures were significantly associated with Parkinson's disease diagnosis, with low-frequency power positively correlating with tremor severity (r = 0.500).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: