Three types of low-shrinkage composites are today commercially available: Ormocers, cationic ring-opening curing systems and highly filled methacrylate-based materials, which cure via free-radical polymerization mechanisms. The aim of this study was to characterize the inorganic fraction of materials belonging to each type and to compare their mechanical properties. Two Ormocers (Admira and an experimental Ormocer V35694), one ring-opening composite (Filtek Silorane) and five methacrylate-based composites Filtek Supreme XT, Tetric EvoCeram, Grandio, Synergy D6 (Coltène-Whaledent, Langenau, Germany) and an experimental material, V34930 were tested. Inorganic fillers were quantified by thermogravimetric analysis and morphologically characterized by scanning electron microscopy. Dynamic modulus was determined by an impulse excitation technique, static elastic moduli and flexural strength by a three-point bending method. The results were analyzed using ANOVA tests (P 0.05). From the present findings, it was suggested that V35694 and Filtek Silorane exhibit comparable properties to conventional methacrylate-based composites, although clinically the cavity type and location must guide material choice. Under high occlusal load, the use of Grandio and V34930 might be favoured. For small cavities, alternative technologies could be preferred as the need for mechanical resistance is lower and the potential for stress generation is greater.
Leprince et al. (Fri,) studied this question.