Key result
Each 1 g increase in contact force during cavotricuspid isthmus ablation was associated with a 16% reduction in the risk of recovered conduction (95% CI 4-27%, P=0.01).
Why the study?
What is the prevalence of low contact force during CTI ablation using traditional markers, and how does it affect acute reconnection?
Observational (n=17)
Blinded to CF measurements
What is the prevalence of low contact force during CTI ablation using traditional markers, and how does it affect acute reconnection?
Reliance on traditional markers of contact during CTI ablation frequently results in low contact force, which is associated with an increased risk of acute reconnection, highlighting the value of real-time CF sensing.
Answers are grounded in this paper and cite their sources.
Real-time contact force sensing may reduce acute reconnection during CTI ablation; leaves open need for RCTs to confirm durable benefit.
INTRODUCTION: Recurrent atrial flutter following cavotricuspid isthmus (CTI) ablation remains a significant problem. The prevalence of low contact force (CF) during CTI ablation using standard tools is unknown. Our aim was to characterize the prevalence of low CF applications when experienced operators performed CTI ablation using "traditional" markers of contact blinded to CF measurements. METHODS AND RESULTS: Average CF (grams, g) and force-time integral (FTI) was analyzed in 458 lesions in 17 patients undergoing CTI ablation. The isthmus was divided into the annular, mid and caval segments for region-specific analysis. Despite "good" contact using traditional markers, there was significant variability in CF within each isthmus segment (e.g., annular CTI 1-57 g). A high proportion of lesions had a CF <10 g (40%). Lowest CF was the annular (median 9 g), followed by the mid (12 g) and the caval CTI (18 g, P < 0.001). Sites of acute CTI re-connection had a lower average CF and FTI than nonreconnected sites (P < 0.05). Each 1 g increase in CF was associated with a 16% reduction in risk of recovered CTI conduction (95% confidence interval: 4-27%, P = 0.01). CONCLUSION: Use of surrogate markers of "good contact" during ablation by experienced operators in the absence of real-time CF sensing resulted in nearly half of all lesions being delivered with low CF with marked region-specific variability in CF. Low CF was implicated in longer time to achieve conduction block and increased risk of acute reconnection. These findings underscore the importance of real-time CF measurements for optimizing ablation of typical atrial flutter.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2015) conducted an observational in Atrial flutter (n=17). Contact force was evaluated on Recovered CTI conduction (16% reduction in risk per 1 g increase, 95% CI 4-27%, p=0.01). Each 1 g increase in contact force during cavotricuspid isthmus ablation was associated with a 16% reduction in the risk of recovered conduction (95% CI 4-27%, P=0.01).