Key result
Undetectable initial troponin I had 100% sensitivity (95% CI 95.2-100%) and NPV (95% CI 98.8-100%) for ruling out myocardial infarction when early presenters (<2 h of symptoms) were excluded.
Why the study?
Does an undetectable initial troponin I level at presentation using a contemporary assay rule out myocardial infarction in patients presenting to the ED with chest pain?
Cohort (n=1,076)
Does an undetectable initial troponin I level at presentation using a contemporary assay rule out myocardial infarction in patients presenting to the ED with chest pain?
An undetectable initial contemporary troponin I level has high sensitivity and negative predictive value for ruling out myocardial infarction, achieving 100% when excluding patients presenting within 2 hours of symptom onset.
Supports ruling out MI with undetectable troponin I after 2 h; leaves open prospective validation before practice change.
AIM: Recent evidence suggests that an undetectable troponin level at emergency department (ED) presentation can rule out the presence of myocardial infarction (MI) in low-risk patients. The aim of this study was to investigate whether an undetectable troponin I (TnI) level at presentation using a contemporary troponin assay can accurately rule out MI at various front-door thrombolysis in myocardial infarction (fTIMI) score cut-offs. METHODS: Planned substudy of a prospective observational cohort study of patients presenting to ED with chest pain without ECG evidence of ischaemia who underwent a 'rule out' acute coronary syndrome process. Clinical, investigational and outcome data were collected. A contemporary TnI assay (Siemens TnI Ultra) was used. Primary outcome of interest was diagnostic accuracy for MI of undetectable initial TnI at presentation at various fTIMI scores (sensitivity, specificity, positive predictive value and negative predictive value (NPV)). RESULTS: 1076 patients were studied, of whom 156 had a final diagnosis of MI (14.5%). For patients with undetectable TnI and fTIMI scores 0, 0-1, 0-2 and 0-6, sensitivities were 98.7%, 98.1%, 97.4% and 97.4%, respectively, specificities were 22.6%, 41.7%, 53.8% and 69.9%, respectively, and NPV were 99%, 99.2%, 99.2% and 99.4%, respectively. If early presenters (<2 h of symptoms) were excluded, undetectable initial troponin had 100% sensitivity (95% CI 95.2% to 100%) and NPV (95% CI 98.8% to 100%). CONCLUSIONS: Using a contemporary TnI assay, undetectable initial TnI has high but not perfect sensitivity and NPV, unless early presenters are excluded. TRIAL REGISTRATION NUMBER: ACTRN12612000990820.
No takes yet. Share an insight, caveat, or question.
Kelly et al. (2014) conducted a cohort in Myocardial infarction (n=1,076). Undetectable initial troponin I was evaluated on Diagnostic accuracy for MI of undetectable initial TnI at presentation at various fTIMI scores (sensitivity, specificity, positive predictive value and negative predictive value). Undetectable initial troponin I had 100% sensitivity (95% CI 95.2-100%) and NPV (95% CI 98.8-100%) for ruling out myocardial infarction when early presenters (<2 h of symptoms) were excluded.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: