Key result
A convolutional neural network predicts maximum ST values from extracted ECG data with ~0.90 AUROC.
Why the study?
Manual analysis of ECG reports is time-consuming and difficult, creating a need for an end-to-end approach to extract raw time-series data from PDF reports and predict ECG features using machine learning.
Can an automated extraction algorithm and machine learning model accurately extract raw ECG data and predict ST elevation from stress test ECG reports?
Can an automated extraction algorithm and machine learning model accurately extract raw ECG data and predict ST elevation from stress test ECG reports?
An automated end-to-end tool successfully extracts raw ECG time-series data from PDF reports and enables accurate machine learning prediction of ST elevation.
Answers are grounded in this paper and cite their sources.
Supports automated ECG analysis feasibility; leaves open prospective validation before clinical adoption.
Background: Manual analysis of ECG reports can be time-consuming and difficult to perform. Machine learning (ML) models have shown higher success when trained on raw time-series rather than images. There is need for an end-to-end approach that starts from extraction of raw data from ECG reports and also predicts ECG features using ML. Hypothesis: A novel automated method that extracts and parses raw time-series ECG data and associated text/numeric data of ST-segment values from PDF ECG reports, may enable prediction of ST elevation by ML. Methods: We collected stress test ECG reports from N=7,622 patients. We split the dataset into 60% for training, 10% for validation and 30% for testing the ML model (fig A). We developed an automated extraction algorithm to extract ECG waveforms and ST elevation values for each stage (baseline, worst case exercise, etc.) of stress test from the PDF ECG reports (fig B). The algorithm uses metadata detection and spatial colocalization techniques to export the ECGs and ST values as JSON files. We then used the ECGs from JSON files to train a Convolutional Neural Network model to predict the max ST value. Performance of extraction algorithm was assessed by visual review of thirty cases comparing the extracted output in fig C to the original PDF. ML model’s performance was assessed using RMSE score and AUROC for predicting max ST value. Results: Review of thirty reports showed a complete accurate match between the original PDF and the extracted results. Figure C shows an example result, where the arrows pointing from a text object to the ECG time-series indicate the respective associations. Fig D shows a truncated output JSON file which was used for ML modeling. The maximum ST value was mostly seen in leads II and V3. ML showed an RMSE of 1.66 on the hold-out test set, and an AUROC of 0.897 (fig E). Conclusion: An automated end-to-end tool that converts PDF vector objects to voltage time series allows preprocessing of raw electrocardiograms for physiological studies and machine learning.
No takes yet. Share an insight, caveat, or question.
Ganesan et al. (2025) studied Stress test ECG (n=7,622). Automated extraction algorithm and Convolutional Neural Network was evaluated on Prediction of max ST value (AUROC 0.897). A Convolutional Neural Network trained on automatically extracted raw ECG time-series data predicted maximum ST values with an RMSE of 1.66 and an AUROC of 0.897.
Synapse has enriched 10 related papers. Consider them for comparative context: