Key result
Lowering holding membrane potential shortens APD90 by ~60% in preclinical patch clamp assays.
Why the study?
High variability of action potentials and methodological settings in neonatal rat ventricular cardiomyocytes hinder comparisons within and between electrophysiological studies.
Methodological variations in patch clamp measurements, such as holding membrane potential and assay duration, significantly alter action potential parameters in neonatal rat ventricular cardiomyocytes, highlighting the need for standardized protocols.
Methodological standardization is required in patch-clamp studies; leaves open optimal parameters for reliable cardiomyocyte data.
Measurement of the ventricular action potential (AP) via whole-cell patch clamp is an important contributor to cardiac electrophysiological research. Neonatal rat ventricular cardiomyocytes (NRVCM) are a commonly used model, in particular for stressor- or drug-related questions. High variability of APs and individual methodological settings hinder comparison both in individual studies and, to an even greater degree, between different projects. This study aims to describe sources of AP heterogeneity in NRVCM related to patch clamp measurement with a focus on resolvable causes. Therefore, AP of NRVCM were induced in whole-cell configuration and measured in current-clamp mode. The effects of varying setup temperature, electrode resistance, resting- (RMP), respectively holding membrane potential (HMP), induction approach, current pulse duration and amplitude plus total assay duration were studied and compared to systematically analyzed literature. We analyzed the impact on different output parameters, namely, maximal upstroke velocity (dV/dt), maximal AP amplitude (APA) and AP duration at different percentages (XX%) of repolarization, APD XX . In a comparative literature research, we found that mean APD 90 in between 27.0 and 560.7 ms (own data 59.7 ± 5.8 ms) were described, with high variability and likely non-Gaussian distribution. In this study, APD 90 , APD 50 and APD 30 , are decreased at more negative RMP (respectively HMP) values. E.g., APD 90 is shortened by ∼60% after lowering HMP from −70 mV to −90 mV) while dV/dt and APA are increased at a more negative HMP. Pulse duration in induction did not affect main AP parameters itself, but induction energy levels above 1.5-fold the threshold energy level increased APA, while APD 50 and APD 90 were shortened. During series of APs at 1 Hz, spike duration (APD 90 ) decreased by ∼27%, with stable AP after the third repetitive AP. Spike duration did also decreased by ∼40% after prolongated measurements for 21 min, indicating degradation of electrophysiological properties. To improve data quality in NRVCM-APs, we suggest using a constant HMP, adjustment of current pulse amplitude to the individual cells’ threshold and the use of repetitive AP-inductions. Finally, we suggest the use of nonparametric statistical methods for statistical analysis. These aspects could reduce variability and lead to more reliable and comparable data.
No takes yet. Share an insight, caveat, or question.
Syren et al. (2025) studied Neonatal rat ventricular cardiomyocytes (NRVCM) (n=48). Patch clamp methodological variations (HMP, induction current, temperature, duration) vs. Baseline or standard patch clamp settings was evaluated on Action potential duration at 90% repolarization (APD90). Lowering holding membrane potential from -70 mV to -90 mV shortened APD90 by approximately 60%, and induction energy levels above 1.5-fold the threshold increased maximal action potential amplitude.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: