Key result
Coronary artery disease without heart failure was associated with an exaggerated increase in systemic vascular resistance during metaboreflex activation.
Why the study?
Does muscle metaboreflex activation reveal impaired hemodynamic responses in individuals with coronary artery disease without overt heart failure compared to healthy controls?
Case-Control (n=23)
Does muscle metaboreflex activation reveal impaired hemodynamic responses in individuals with coronary artery disease without overt heart failure compared to healthy controls?
Individuals with CAD without overt heart failure show early signs of diastolic dysfunction and exaggerated vasoconstriction during metaboreflex activation compared to healthy controls.
Answers are grounded in this paper and cite their sources.
Suggests early diastolic dysfunction in CAD without HF; hypothesis-generating for metaboreflex testing in risk stratification.
This study was devised to investigate the effect of coronary artery disease (CAD) without overt signs of heart failure on the cardiovascular responses to muscle metaboreflex activation. We hypothesized that any CAD-induced preclinical systolic and/or diastolic dysfunction could impair hemodynamic response to the metaboreflex test. Twelve men diagnosed with CAD without any sign or symptoms of heart failure and 11 age-matched healthy control (CTL) subjects participated in the study. Subjects performed a postexercise muscle ischemia (PEMI) test to activate the metaboreflex. They also performed a control exercise recovery test to compare data from the PEMI test. The main results were that the CAD group reached a similar mean arterial blood pressure response as the CTL group during PEMI. However, the mechanism by which this response was achieved was different between groups. In particular, CAD achieved the target mean arterial blood pressure by increasing systemic vascular resistance (+383.8 ± 256.6 vs. +91.2 ± 293.5 dyn·s−1·cm−5 for the CAD and CTL groups, respectively), the CTL group by increasing cardiac preload (−0.92 ± 8.53 vs. 5.34 ± 4.29 ml in end-diastolic volume for the CAD and CTL groups, respectively), which led to an enhanced stroke volume and cardiac output. Furthermore, the ventricular filling rate response was higher in the CTL group than in the CAD group during PEMI (P < 0.05 for all comparisons). This study confirms that diastolic function is pivotal for normal hemodynamics during the metaboreflex. Moreover, it provides evidence that early signs of diastolic impairment attributable to CAD can be detected by the metaboreflex test. NEW & NOTEWORTHY Individuals suffering from coronary artery disease without overt signs of heart failure may show early signs of diastolic dysfunction, which can be detected by the metaboreflex test. During the metaboreflex, these subjects show impaired preload and stroke volume responses and exaggerated vasoconstriction compared with controls.
No takes yet. Share an insight, caveat, or question.
Magnani et al. (2017) conducted a case-control in Coronary artery disease without overt signs or symptoms of heart failure (n=23). Coronary artery disease vs. Healthy controls was evaluated on Change in systemic vascular resistance during postexercise muscle ischemia (dyn·s−1·cm−5) (p=<0.05). Coronary artery disease without heart failure was associated with an exaggerated increase in systemic vascular resistance during metaboreflex activation.
Synapse has enriched 10 related papers. Consider them for comparative context: