Optimization of experimental settings of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), like the contrast administration protocol, is of great importance for reliable quantification of the microcirculatory properties, such as the volume transfer-constant K(trans). Using system identification theory and computer simulations, the confounding effects of volume, rate and multiplicity of a contrast injection on the reliability of K(trans) estimation was assessed. A new tracer-distribution model (TDM), based on in vivo data from rectal cancer patients, served to describe the relationship between the contrast agent injection and the blood time-course. A pharmacokinetic model (PKM) was used to describe the relation between the blood and tumor tissue time-courses. By means of TDM and PKM in series, the tissue-transfer function of the PKM was analyzed. As both the TDM and PKM represented low-frequency-pass filters, the energy-density at low frequencies of the blood and tissue time-courses was larger than at high frequencies. The simulations, based on measurements in humans, predict that the K(trans) is most reliable with a high injection volume administered in a single injection, where high rates only modestly improve K(trans).
No takes yet. Share an insight, caveat, or question.
Aerts et al. (2008) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: