Key result
Multiple same-day self blood pressure measurements provided comparable readings to daytime ambulatory monitoring, though ABPM hourly averages were slightly lower (3.3 mmHg systolic, P<0.05).
Why the study?
Does multiple same-day self blood pressure monitoring provide comparable information to ambulatory blood pressure monitoring in normotensive and hypertensive patients?
Cross-Sectional (n=97)
Does multiple same-day self blood pressure monitoring provide comparable information to ambulatory blood pressure monitoring in normotensive and hypertensive patients?
Multiple self-measurements throughout the day provide comparable blood pressure information to daytime ABPM and are preferred by most patients.
Answers are grounded in this paper and cite their sources.
May support self BP monitoring as comparable alternative to daytime ABPM; hypothesis-generating and should not yet change practice.
BACKGROUND AND AIM: The relative roles of self and ambulatory blood pressure monitoring (self BPM, ABPM, respectively) have yet to be clearly defined despite accumulating evidence of self BPM benefits, particularly in hypertension management. In particular, measurements comparable to ABPM have been documented with self-measurement, usually twice daily over one or more days. Nevertheless, ABPM offers a series of recordings performed throughout the day that can be invaluable during drug treatment. Consequently, this study evaluated 18 normotensive and 79 hypertensive patients, including 21 not taking hypotensive agents, and measured their blood pressure at least every 2 h while they were also undergoing ABPM. METHODS AND RESULTS: Self-measurement was performed between five and 12 times during the day with 77% of subjects preferring self BPM rather than daytime ABPM. When compared with the closest ABP measurement, mean systolic and diastolic pressures were not significantly different throughout the day in both normotensive and hypertensive patients. However, a comparison of a series of ABPM hourly averages (three readings performed closest to the respective self BPM reading) throughout the day in all hypertensive subjects found ABPM readings to be slightly but significantly lower (3.3 systolic, 2.2 mmHg diastolic; P < 0.05). CONCLUSION: It is concluded that multiple self-measurements throughout the day provides comparable information to daytime ABPM, is preferred by most patients, and should be a cost-effective alternative in the diagnosis and management of hypertension.
No takes yet. Share an insight, caveat, or question.
Carney et al. (2005) conducted a cross-sectional in Hypertension (n=97). Self blood pressure monitoring (self BPM) vs. Ambulatory blood pressure monitoring (ABPM) was evaluated on Blood pressure measurements (systolic and diastolic) (MD 3.3 mmHg systolic, 2.2 mmHg diastolic, p=< 0.05). Multiple same-day self blood pressure measurements provided comparable readings to daytime ambulatory monitoring, though ABPM hourly averages were slightly lower (3.3 mmHg systolic, P<0.05).
Synapse has enriched 10 related papers. Consider them for comparative context: